1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-01-394-8251

5925-01-394-8251

Find complete technical information, availability, and procurement data for: 5925-01-394-8251

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-394-8251 to receive an up to date pricing and availability quote by email.

5925-01-394-8251
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-394-8251
Item Name Code
00136
Assigment Date
08/16/1994 (31 years ago)

0.625 inches nominal bushing length, 2.094 inches nominal center to center distance between terminals parallel to length, multipole-single actuator type body style, 2.265 inches maximum body length, 2.265 inches maximum body width

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
multipole-single actuator type
Bushing Length
0.625 inches nominal
Body Length
2.265 inches maximum
Body Width
2.265 inches maximum
Center To Center Distance Between Terminals Parallel To Length
2.094 inches nominal
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
Switch Contact Arrangement
single pole, double throw
Mounting Surface To Terminal End Distance
2.790 inches maximum
Pole Quantity
3
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
40.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
magnetic all locations
Trip Release Characteristic
time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole two
Auxiliary Switch Function And Quantity
1 alarm
Internal Trip Release Configuration
series trip all locations
Nominal Thread Size
0.300 inches
Switch Location And Position Designation
internal at pole three
Trip Delay Time In Seconds Per Rated Continuous Current
10.000 minimum at 200 pct and 150.000 maximum at 200 pct all locations
Switch Terminal Type
screw
Switch Current Rating And Type In Amps
10.0 ac and 3.0 dc
Switch Voltage Rating And Type In Volts
250.0 ac and 50.0 dc
Frequency In Hertz
60.0 all locations
Thread Series Designator
un
Terminal Type And Quantity
6 screw

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
1211447-201 Circuit Breaker
IALN111-1REC4-23340-1 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-394-8251?
The FSCG of the NSN 5925-01-394-8251 is 5925
Does the NSN 5925-01-394-8251 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-394-8251 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-394-8251 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-394-8251 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-394-8251 was assigned to the Federal Catalog?
It was assigned 31 years ago, on Tue, Aug 16, 1994

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

M22759/11-24-9126
6145-01-090-6458
Electrical Wire
M22759/11-24-9127
6145-01-087-4933
Electrical Wire
M22759/11-24-9128
6145-01-088-5445
Electrical Wire
M22759/11-24-913
6145-00-257-6784
Electrical Wire
M22759/11-24-9134
6145-01-098-0116
Electrical Wire
M22759/11-24-9135
6145-01-095-3422
Electrical Wire
M22759/11-24-9136
6145-01-098-0117
Electrical Wire
M22759/11-24-9137
6145-01-096-5649
Electrical Wire
M22759/11-24-9138
6145-01-099-9111
Electrical Wire
M22759/11-24-914
6145-00-244-4529
Electrical Wire
M22759/11-24-9145
6145-01-096-2502
Electrical Wire
M22759/11-24-9146
6145-01-099-9110
Electrical Wire
M22759/11-24-9147
6145-01-102-2825
Electrical Wire
M22759/11-24-9148
6145-01-098-0123
Electrical Wire
M22759/11-24-915
6145-00-244-4497
Electrical Wire