1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-01-390-3494

5925-01-390-3494

Find complete technical information, availability, and procurement data for: 5925-01-390-3494

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-390-3494 to receive an up to date pricing and availability quote by email.

5925-01-390-3494
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-390-3494
Item Name Code
00136
Assigment Date
05/17/1994 (32 years ago)

Two or more complete switches mounted on each other or having a common mounting the major function of which is to hold the switches. Each switch, as a separable item, must be capable of functioning in accordance with its own name. Excludes:items consisting of individually separable switches which are physically interlocked (e.g., one button returns when the other is pushed), which have a common actuator, or are electrically connected. See also switch, push.

1.500 inches maximum body length, 0.380 inches nominal bushing length, single pole type body style, 0.625 inches maximum body width, 0.875 inches nominal center to center distance between terminals parallel to length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Bushing Length
0.380 inches nominal
Body Length
1.500 inches maximum
Body Width
0.625 inches maximum
Center To Center Distance Between Terminals Parallel To Length
0.875 inches nominal
Mounting Surface To Terminal End Distance
1.865 inches nominal
Pole Quantity
1
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac single location
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 ac single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.380 inches
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 minimum at 200 pct and 6.000 maximum at 200 pct single location
Frequency In Hertz
60.0 single location
Thread Series Designator
unc
Terminal Type And Quantity
2 wire hook

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
10867500-02 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-390-3494?
The FSCG of the NSN 5925-01-390-3494 is 5925
Does the NSN 5925-01-390-3494 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-390-3494 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-390-3494 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-390-3494 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-390-3494 was assigned to the Federal Catalog?
It was assigned 32 years ago, on Tue, May 17, 1994

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

94F3623
6220-01-631-7504
Panel Light
94F4
4730-00-906-1527
Tube to Boss Elbow
94F4528
5340-01-577-0588
Spacing Threaded Standoff
94F4769
5975-01-572-9783
Electrical-Electronic Equi Panel
94F548TP
5910-01-128-9453
Paper Dielectric Fixed Capacitor
94F5874
5920-01-381-8688
Cartridge Fuse
94F5914
5920-01-250-3298
Cartridge Fuse
94F688
5340-01-537-9973
Spacing Threaded Standoff
94F70G198
6350-00-721-7760
Fire Detector Sy Sensing Element
94F7277
6110-01-473-8651
Voltage Regulator
94F7278
4320-01-472-6468
Hydraulic Motor-Pump
94F7283
7050-01-472-6470
Indicator Panel
94F7314
3895-01-472-6471
Engine Dri Cable Reeling Machine
94F7315
3895-01-472-6472
Engine Dri Cable Reeling Machine
94F7360
7025-01-495-1727
Disk and Tape Drive Unit