DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-319-1092 to receive an up to date pricing and availability quote by email.

5925-01-319-1092
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-319-1092
Item Name Code
00136
Assigment Date
05/02/1990 (36 years ago)

multipole-single actuator type body style, 0.380 inches maximum bushing length, 1.875 inches maximum body width, 0.875 inches nominal center to center distance between terminals parallel to length, 1.500 inches maximum body length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
multipole-single actuator type
Bushing Length
0.380 inches maximum
Body Length
1.500 inches maximum
Body Width
1.875 inches maximum
Center To Center Distance Between Terminals Parallel To Length
0.875 inches nominal
Center To Center Distance Between Terminals Parallel To Width
0.625 inches nominal
Nonturn Device Radius
0.625 inches nominal
Nonturn Device Length
0.130 inches nominal
Nonturn Device Diameter
0.140 inches nominal
Switch Contact Arrangement
single pole, double throw
Fragility Factor
moderately rugged
Mounting Surface To Terminal End Distance
1.780 inches maximum
Pole Quantity
3
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
Storage Type
general purpose warehouse
Special Handling Feature
magnetic
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
7.0 amperes ac second location
Maximum Continuous Load Current Rating Per Pole
7.0 amperes ac third location
Maximum Continuous Load Current Rating Per Pole
8.0 amperes ac first location
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
magnetic all locations
Trip Release Characteristic
time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole two
Auxiliary Switch Function And Quantity
1 alarm
Internal Trip Release Configuration
series trip all locations
Nominal Thread Size
0.375 inches
Switch Location And Position Designation
internal at pole one
Trip Delay Time In Seconds Per Rated Continuous Current
0.350 minimum at 200 pct and 1.000 maximum at 200 pct all locations
Inclosure Protection Type For Which Designed
hermetically sealed
Switch Terminal Type
tab, solder lug
Switch Current Rating And Type In Amps
0.5 ac and 0.5 dc
Switch Voltage Rating And Type In Volts
120.0 ac and 50.0 dc
Frequency In Hertz
60.0 all locations
Thread Series Designator
unef
Terminal Type And Quantity
6 tab w/screw

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
179006P2 Circuit Breaker
AP-116-4147-2 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-319-1092?
The FSCG of the NSN 5925-01-319-1092 is 5925
Does the NSN 5925-01-319-1092 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-319-1092 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-319-1092 contain precious materials?
Precious metal content is unknown
Does NSN 5925-01-319-1092 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-319-1092 was assigned to the Federal Catalog?
It was assigned 36 years ago, on Wed, May 2, 1990

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

16W200-13
5340-01-524-6970
Nut and Bolt Locking Plate
16W200-14
5340-01-523-2645
Nut and Bolt Locking Plate
16W200-7
5340-01-144-9915
Nut and Bolt Locking Plate
16W200-9
5342-01-144-9920
Lock Plate
16W211-21
1560-01-561-5867
Airfoil Rib
16W211-22
1560-01-553-7009
Airfoil Rib
16W212-11
1560-01-561-7737
Airfoil Rib
16W212-12
1560-01-266-1768
Airfoil Rib
16W213
1560-01-706-4928
Air Structural Component Fitting
16W213-10
1560-01-706-4928
Air Structural Component Fitting
16W213-9
1560-01-706-4932
Air Structural Component Fitting
16W221-11
1560-01-553-4121
Airfoil Rib
16W221-12
1560-01-553-1249
Airfoil Rib
16W22124
5910-00-378-9598
Capacitor
16W2249
6220-00-350-2202
Adapter