Find complete technical information, availability, and procurement data for: 5925-01-311-3650

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-311-3650 to receive an up to date pricing and availability quote by email.

5925-01-311-3650
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-311-3650
Item Name Code
00136
Assigment Date
11/24/1989 (36 years ago)

"a device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes:circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller."

7.249 inches nominal center to center distance between terminals parallel to length, 8.250 inches nominal body width, 2.750 inches nominal center to center distance between terminals parallel to width, multipole-single actuator type body style, 10.125 inches nominal body length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
multipole-single actuator type
Body Length
10.125 inches nominal
Body Width
8.250 inches nominal
Center To Center Distance Between Terminals Parallel To Length
7.249 inches nominal
Center To Center Distance Between Terminals Parallel To Width
2.750 inches nominal
Unthreaded Mounting Hole Diameter
0.196 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
7.250 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
2.750 inches nominal
Fragility Factor
moderately rugged
Boss Height
0.219 inches nominal
Mounting Surface To Terminal End Distance
3.812 inches nominal
Pole Quantity
3
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
4 unthreaded hole
Storage Type
general purpose warehouse
Special Handling Feature
magnetic
Features Provided
adjustable trip release
Maximum Continuous Load Current Rating Per Pole
350.0 amperes ac and 350.0 amperes dc all locations
Operating Voltage Type And Rating Per Pole In Volts
480.0 ac and 250.0 dc all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
30000.0 ac and 10000.0 dc all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
thermal-magnetic all locations
Trip Release Characteristic
instantaneous all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole two
Adjustable Trip Setting Current Range Per Pole In Amps
+1750.0 to 3150.0 ac and +1750.0 to 3150.0 dc all locations
Inclosure Protection Type For Which Designed
dustproof
Trip Release Ambient Temp Rating
40.0 celsius nominal all locations
Frequency In Hertz
60.0 all locations
Material
plastic case
Terminal Type And Quantity
6 compression

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
NJL431350 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-311-3650?
The FSCG of the NSN 5925-01-311-3650 is 5925
Does the NSN 5925-01-311-3650 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-311-3650 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-311-3650 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-311-3650 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-311-3650 was assigned to the Federal Catalog?
It was assigned 36 years ago, on Fri, Nov 24, 1989

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

USGS 24K44776
7643-01-637-3396
Topographic Geospatial Products
USGS 24K44777
7643-01-640-0321
Topographic Geospatial Products
USGS 24K44778
7643-01-635-9891
Topographic Geospatial Products
USGS 24K44779
7643-01-638-8012
Topographic Geospatial Products
USGS 24K4478
7643-01-639-9113
Topographic Geospatial Products
USGS 24K44780
7643-01-636-2105
Topographic Geospatial Products
USGS 24K44781
7643-01-638-6142
Topographic Geospatial Products
USGS 24K44782
7643-01-640-0322
Topographic Geospatial Products
USGS 24K44783
7643-01-640-2693
Topographic Geospatial Products
USGS 24K44784
7643-01-637-8166
Topographic Geospatial Products
USGS 24K44785
7643-01-640-6023
Topographic Geospatial Products
USGS 24K44786
7643-01-640-6020
Topographic Geospatial Products
USGS 24K44787
7643-01-640-0325
Topographic Geospatial Products
USGS 24K44788
7643-01-635-5228
Topographic Geospatial Products
USGS 24K44789
7643-01-640-0331
Topographic Geospatial Products