1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-01-297-5777

5925-01-297-5777

Find complete technical information, availability, and procurement data for: 5925-01-297-5777

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-297-5777 to receive an up to date pricing and availability quote by email.

5925-01-297-5777
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-297-5777
Item Name Code
00136
Assigment Date
04/04/1989 (37 years ago)

A fuse in which the element is inclosed in a cylindrical body. The element may be renewable. The terminals may be of varying types. It may contain a visual indication that the fusible element is severed, and may also provide an audible alarm through auxiliary circuitry. For noncylindrical items, see fuse, inclosed link.

2.480 inches minimum and 2.500 inches maximum body length, 1.925 inches minimum and 1.955 inches maximum center to center distance between terminals parallel to length, 0.735 inches minimum and 0.765 inches maximum center to center distance between terminals parallel to width, 1.515 inches maximum body width, multipole-multiple actuator type body style

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
multipole-multiple actuator type
Body Length
2.480 inches minimum and 2.500 inches maximum
Body Width
1.515 inches maximum
Center To Center Distance Between Terminals Parallel To Length
1.925 inches minimum and 1.955 inches maximum
Center To Center Distance Between Terminals Parallel To Width
0.735 inches minimum and 0.765 inches maximum
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.050 inches minimum and 2.070 inches maximum
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.735 inches minimum and 0.765 inches maximum
Fragility Factor
moderately rugged
Boss Height
0.135 inches minimum and 0.165 inches maximum
Mounting Surface To Terminal End Distance
2.625 inches maximum
Pole Quantity
2
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
4 threaded hole
Storage Type
general purpose warehouse
Special Handling Feature
magnetic
Features Provided
high inrush protection
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
50.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
magnetic all locations
Trip Release Characteristic
time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
2 toggle
Actuator Function
trip-reset
Actuator Position Designation
at each pole
External Actuator Linkage Arrangement
one and two linked
Internal Trip Release Configuration
series trip all locations
Nominal Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 minimum at 200 pct and 20.000 maximum at 200 pct all locations
Inclosure Protection Type For Which Designed
corrosion resistant and moisture resistant and shockproof and vibrationproof and fungus resistant
Unpackaged Unit Weight
7.400 ounces nominal
Frequency In Hertz
60.0 all locations
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
4 threaded stud

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
711586-1 Circuit Breaker
AM2Z347-1 Circuit Breaker
APL11-8764-1 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-297-5777?
The FSCG of the NSN 5925-01-297-5777 is 5925
Does the NSN 5925-01-297-5777 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-297-5777 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-297-5777 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-297-5777 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-297-5777 was assigned to the Federal Catalog?
It was assigned 37 years ago, on Tue, Apr 4, 1989

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

FRE18263-1
5950-00-235-6490
Reactor
FRE18277-1
5950-00-235-6854
Audio Frequency Transformer
FRE18277-1C
5950-00-235-6854
Audio Frequency Transformer
FRE18305-1C
5950-00-647-6006
Audio Frequency Transformer
FRE18437-1
5950-00-557-6274
Power Transformer
FRE18437-1C
5950-00-557-6274
Power Transformer
FRE18772-1-1
5950-00-387-5716
Electromagnetic Component Core
FRE18772-1-2
5950-00-387-5717
Electromagnetic Component Core
FRE19471-3-2
5905-00-248-6131
Resistor,variable,nonwire Wound,
FRE19525-1
5950-00-246-4461
Reactor
FRE19952-1-1
5910-00-195-5493
Mica Dielectric Fixed Capacitor
FRE19953-1-1
5910-00-184-3094
Mica Dielectric Fixed Capacitor
FRE19953 1-2
5910-00-256-5593
Mica Dielectric Fixed Capacitor
FRE19953-1-3
5910-00-174-5105
Mica Dielectric Fixed Capacitor
FRE19953-1-3H
5910-00-174-5105
Mica Dielectric Fixed Capacitor