CED63M040

View detailed technical data, stock status, and sourcing information for: CED63M040

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for part CED63M040 to receive an up to date pricing and availability quote by email.

CED63M040
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-294-4579
Item Name Code
00136
Assigment Date
02/16/1989 (37 years ago)

"a device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes:circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller."

4.000 inches nominal overall width, 9.578 inches nominal overall length, 0.250 inches nominal unthreaded mounting hole diameter, 3.000 inches nominal overall height, rectangular dimensional envelope body style

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
rectangular dimensional envelope
Overall Length
9.578 inches nominal
Overall Height
3.000 inches nominal
Overall Width
4.000 inches nominal
Unthreaded Mounting Hole Diameter
0.250 inches nominal
Fragility Factor
moderately rugged
Pole Quantity
3
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
4 unthreaded hole
Storage Type
general purpose warehouse
Special Handling Feature
magnetic
Maximum Continuous Load Current Rating Per Pole
40.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
600.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
18000.0 ac all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
thermal-magnetic all locations
Trip Release Characteristic
instantaneous all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole two
Inclosure Protection Type For Which Designed
dustproof
Trip Release Ambient Temp Rating
50.0 celsius nominal all locations
Frequency In Hertz
60.0 all locations
Material
plastic case
Terminal Type And Quantity
6 compression

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
CED63M040 Circuit Breaker
CLE63M040 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-294-4579?
The FSCG of the NSN 5925-01-294-4579 is 5925
Does the NSN 5925-01-294-4579 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-294-4579 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-294-4579 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-294-4579 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-294-4579 was assigned to the Federal Catalog?
It was assigned 37 years ago, on Thu, Feb 16, 1989

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

5PTV4216-127
1560-01-707-5104
Radius Block
5PTV4216-129
5365-01-707-4597
Shim
5PTV4216-131
5365-01-707-4601
Shim
5PTV4501-101
5915-01-498-3435
Band Pass Filter
5PTV4801-001
6110-01-488-9153
Magnetic Contactor
5PTV4801-002
5945-01-488-2567
Electromagnetic Relay
5PTV4802-25F
5925-01-488-8967
Circuit Breaker
5PTV4805-10BN-2
6150-01-489-0995
Conductor Bus
5PTV4805-10BN-4
6150-01-489-0996
Conductor Bus
5PTV4805-10BN-6
6150-01-489-0997
Conductor Bus
5PTV4806-101
5961-01-490-4880
Diode Semiconductor Device
5PTV4807-101
5961-01-493-3949
Diode Semiconductor Device
5PTV4809-104
5340-01-488-1860
Mount
5PTV4810-101
5340-01-488-1861
Mount
5PTV4811-101
5935-01-486-7240
Electrical Connector Assembly