13MC1-205-20
View detailed technical data, stock status, and sourcing information for: 13MC1-205-20
DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for part 13MC1-205-20 to receive an up to date pricing and availability quote by email.
"a device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes:circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller."
2.485 inches minimum and 2.515 inches maximum body length, 2.299 inches minimum and 2.301 inches maximum body width, single pole, double throw switch contact arrangement, multipole-multiple actuator type body style, 0.735 inches minimum and 0.765 inches maximum center to center distance between terminals parallel to width
Product Characteristics
Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.
- Body Style
- multipole-multiple actuator type
- Body Length
- 2.485 inches minimum and 2.515 inches maximum
- Body Width
- 2.299 inches minimum and 2.301 inches maximum
- Center To Center Distance Between Terminals Parallel To Width
- 0.735 inches minimum and 0.765 inches maximum
- Switch Contact Arrangement
- single pole, double throw
- Fragility Factor
- moderately rugged
- Boss Height
- 0.130 inches minimum and 0.150 inches maximum
- Mounting Surface To Terminal End Distance
- 2.409 inches minimum and 2.533 inches maximum
- Pole Quantity
- 3
- Arc Quenching Method
- magnetic blowout
- Mounting Facility Type And Quantity
- 6 threaded hole
- Storage Type
- general purpose warehouse
- Special Handling Feature
- magnetic
- Thread Quantity Per Inch
- 32
- Maximum Continuous Load Current Rating Per Pole
- 20.0 amperes ac all locations
- Operating Voltage Type And Rating Per Pole In Volts
- 250.0 ac all locations
- Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
- 1000.0 ac all locations
- Circuit Protection Type
- overcurrent all locations
- Trip Release Method
- magnetic all locations
- Trip Release Characteristic
- time delay all locations
- Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
- 150.0 all locations
- Reset Method
- manual
- Main Contact Tripping Mechanism Type
- trip free
- Manual Actuator Type And Quantity
- 3 toggle
- Actuator Function
- trip-reset
- Actuator Position Designation
- at each pole
- External Actuator Linkage Arrangement
- one, two, and three linked
- Auxiliary Switch Function And Quantity
- 1 alarm
- Internal Trip Release Configuration
- series trip all locations
- Nominal Thread Size
- 0.138 inches
- Switch Location And Position Designation
- internal at pole one
- Trip Delay Time In Seconds Per Rated Continuous Current
- 20.000 minimum at 200 pct and 70.000 maximum at 200 pct all locations
- Inclosure Protection Type For Which Designed
- fungus resistant and moisture resistant and shock resistant and humidity resistant and salt spray proof
- Switch Terminal Type
- tab, solder lug
- Switch Current Rating And Type In Amps
- 2.5 ac and 1.0 dc
- Switch Voltage Rating And Type In Volts
- 250.0 ac and 50.0 dc
- Unpackaged Unit Weight
- 14.250 ounces nominal
- Frequency In Hertz
- 400.0 all locations
- Material
- plastic case
- Thread Series Designator
- unc
- Terminal Type And Quantity
- 6 threaded stud
Related Parts
This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:
| Part Number | Name |
|---|---|
| 13MC1-205-20 | Circuit Breaker |
| 260-4015-500 | Circuit Breaker |
| AM333HEMG6-20-14 | Circuit Breaker |
| AM333HEMG6-20-250-14-400 | Circuit Breaker |
FAQs
Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.
What is the FSCG of the NSN 5925-01-293-9165?
Does the NSN 5925-01-293-9165 have a Schedule B code assigned?
Does NSN 5925-01-293-9165 require demilitarization?
Does NSN 5925-01-293-9165 contain precious materials?
Does NSN 5925-01-293-9165 contain hazardous materials?
When the NSN 5925-01-293-9165 was assigned to the Federal Catalog?
Professional Distribution
Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.
- ITAR Registered
- DDTC Registered
- HAZMAT Certified
- AS9120 Quality Standards
- 100% Quality Inspections
You May Also Like
Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.
Pricing
Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information: