5925-01-291-5508

Find complete technical information, availability, and procurement data for: 5925-01-291-5508

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-291-5508 to receive an up to date pricing and availability quote by email.

5925-01-291-5508
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-291-5508
Item Name Code
00136
Assigment Date
12/30/1988 (37 years ago)

single pole type body style, 0.548 inches minimum and 0.648 inches maximum bushing length, 1.209 inches minimum and 1.271 inches maximum center to center distance between terminals parallel to length, 1.761 inches maximum body length, 0.656 inches maximum body width

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Bushing Length
0.548 inches minimum and 0.648 inches maximum
Body Length
1.761 inches maximum
Body Width
0.656 inches maximum
Center To Center Distance Between Terminals Parallel To Length
1.209 inches minimum and 1.271 inches maximum
Fragility Factor
moderately rugged
End Item Identification
aircraft stratolifter c-135
Mounting Surface To Terminal End Distance
1.776 inches minimum and 1.838 inches maximum
Pole Quantity
1
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
1 threaded bushing
Storage Type
general purpose warehouse
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
3.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
32.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 dc single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 push-pull
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.468 inches
Trip Delay Time In Seconds Per Rated Continuous Current
0.003 minimum at 200 pct and 1.500 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
dustproof
Criticality Code Justification
feat
Special Features
weapon system essential
Material
plastic case
Thread Series Designator
uns
Terminal Type And Quantity
2 tab w/screw

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
18100357-001 Circuit Breaker
7MC49-3-3 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-291-5508?
The FSCG of the NSN 5925-01-291-5508 is 5925
Does the NSN 5925-01-291-5508 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-291-5508 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-291-5508 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-291-5508 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-291-5508 was assigned to the Federal Catalog?
It was assigned 37 years ago, on Fri, Dec 30, 1988

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

9-61963-30
1560-00-333-6776
Aircraft Structural Panel
9-61963-3041
1560-00-333-6777
Aircraft Structural Panel
9-61963-4
1560-00-320-4962
Aircraft Structural Panel
9-61963-5
1560-00-333-6777
Aircraft Structural Panel
9-61963-6
1560-00-333-6778
Aircraft Structural Panel
9-61964
1560-01-649-1419
Aircraft Wing Fairing
9-61964-1
1560-00-386-4205
Aircraft Fairing
9-61964-2
1560-00-169-1740
Aircraft Fairing
9-61964-2001
1560-01-649-1564
Aircraft Wing Fairing
9-61964-2002
1560-01-649-1419
Aircraft Wing Fairing
9-61982-1
1560-01-602-7939
Air Structural Component Support
9-61982-2
1560-01-602-7941
Angle Splice
9-61996
1560-00-332-2708
Emergency Flap Drive Cap
9-62
5930-00-441-0615
Switch Subassembly
9-62-2002
5905-01-273-6647
Resistor,variable,wire Wound,non