5925-01-287-4283
Find complete technical information, availability, and procurement data for: 5925-01-287-4283
DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-287-4283 to receive an up to date pricing and availability quote by email.
"a device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes:circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller."
2.968 inches minimum and 3.032 inches maximum body width, multipole-multiple actuator type body style, 2.468 inches minimum and 2.532 inches maximum body length, 1.906 inches minimum and 1.970 inches maximum center to center distance between terminals parallel to length, 0.722 inches minimum and 0.782 inches maximum center to center distance between terminals parallel to width
Product Characteristics
Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.
- Body Style
- multipole-multiple actuator type
- Body Length
- 2.468 inches minimum and 2.532 inches maximum
- Body Width
- 2.968 inches minimum and 3.032 inches maximum
- Center To Center Distance Between Terminals Parallel To Length
- 1.906 inches minimum and 1.970 inches maximum
- Center To Center Distance Between Terminals Parallel To Width
- 0.722 inches minimum and 0.782 inches maximum
- Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
- 2.030 inches minimum and 2.094 inches maximum
- Switch Contact Arrangement
- single pole, double throw
- Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
- 0.722 inches minimum and 0.782 inches maximum
- Boss Height
- 0.140 inches minimum and 0.172 inches maximum
- Mounting Surface To Terminal End Distance
- 2.688 inches minimum and 2.752 inches maximum
- Pole Quantity
- 4
- Mounting Facility Type And Quantity
- 8 threaded hole
- Thread Quantity Per Inch
- 32
- Maximum Continuous Load Current Rating Per Pole
- 50.0 amperes ac first location
- Maximum Continuous Load Current Rating Per Pole
- 50.0 amperes ac second location
- Maximum Continuous Load Current Rating Per Pole
- 50.0 amperes ac third location
- Operating Voltage Type And Rating Per Pole In Volts
- 250.0 ac second location
- Operating Voltage Type And Rating Per Pole In Volts
- 250.0 ac third location
- Operating Voltage Type And Rating Per Pole In Volts
- 250.0 ac first location
- Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
- 1000.0 ac first location
- Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
- 1000.0 ac second location
- Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
- 1000.0 ac third location
- Circuit Protection Type
- overcurrent first location
- Circuit Protection Type
- overcurrent second location
- Circuit Protection Type
- overcurrent third location
- Trip Release Method
- magnetic-hydraulic second location
- Trip Release Method
- magnetic-hydraulic third location
- Trip Release Method
- magnetic-hydraulic first location
- Trip Release Characteristic
- time delay first location
- Trip Release Characteristic
- time delay second location
- Trip Release Characteristic
- time delay third location
- Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
- 125.0 first location
- Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
- 125.0 second location
- Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
- 125.0 third location
- Reset Method
- manual
- Main Contact Tripping Mechanism Type
- trip free
- Manual Actuator Type And Quantity
- 4 toggle
- Actuator Function
- trip-reset
- Actuator Position Designation
- at each pole
- External Actuator Linkage Arrangement
- one, two, three, and four linked
- Auxiliary Switch Function And Quantity
- 1 alarm
- Internal Trip Release Configuration
- series trip first location
- Internal Trip Release Configuration
- series trip second location
- Internal Trip Release Configuration
- series trip third location
- Nominal Thread Size
- 0.138 inches
- Switch Location And Position Designation
- external at pole four
- Trip Delay Time In Seconds Per Rated Continuous Current
- 2.000 minimum at 200 pct and 20.000 maximum at 200 pct first location
- Trip Delay Time In Seconds Per Rated Continuous Current
- 2.000 minimum at 200 pct and 20.000 maximum at 200 pct second location
- Trip Delay Time In Seconds Per Rated Continuous Current
- 2.000 minimum at 200 pct and 20.000 maximum at 200 pct third location
- Inclosure Protection Type For Which Designed
- fungus resistant and humidity resistant and moisture resistant and shock resistant and vibration resistant
- Switch Terminal Type
- threaded stud
- Switch Current Rating And Type In Amps
- 50.0 ac
- Switch Voltage Rating And Type In Volts
- 250.0 ac
- Unpackaged Unit Weight
- 9.500 ounces nominal
- Special Features
- fourth pole is switch only
- Frequency In Hertz
- 50.0 or 60.0 fourth location
- Frequency In Hertz
- 60.0 first location
- Frequency In Hertz
- 60.0 third location
- Frequency In Hertz
- 60.0 second location
- Material
- plastic case
- Thread Series Designator
- unc
- Terminal Type And Quantity
- 8 threaded stud
Related Parts
This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:
| Part Number | Name |
|---|---|
| 11426-90003 | Circuit Breaker |
| AM4-A3A3A3A6-A-50-2 | Circuit Breaker |
| UPL5111-22195-1 | Circuit Breaker |
FAQs
Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.
What is the FSCG of the NSN 5925-01-287-4283?
Does the NSN 5925-01-287-4283 have a Schedule B code assigned?
Does NSN 5925-01-287-4283 require demilitarization?
Does NSN 5925-01-287-4283 contain precious materials?
Does NSN 5925-01-287-4283 contain hazardous materials?
When the NSN 5925-01-287-4283 was assigned to the Federal Catalog?
Professional Distribution
Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.