1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-01-286-2805

5925-01-286-2805

Find complete technical information, availability, and procurement data for: 5925-01-286-2805

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-286-2805 to receive an up to date pricing and availability quote by email.

5925-01-286-2805
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-286-2805
Item Name Code
00136
Assigment Date
09/29/1988 (37 years ago)

A relay which is actuated by the effect of a magnetic field developed by the current in its energizing coil(s). Includes solenoid and armature types. Excludes:contactor, magnetic; relay, meter movement; relay, motor driven; relay, reed; relay, resonant reed; relay, rotary; and switch, stepping.

1.770 inches maximum overall width, moderately rugged fragility factor, 1.510 inches minimum and 1.570 inches maximum overall height, rectangular dimensional envelope body style, 1.970 inches minimum and 2.030 inches maximum overall length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
rectangular dimensional envelope
Overall Length
1.970 inches minimum and 2.030 inches maximum
Overall Height
1.510 inches minimum and 1.570 inches maximum
Overall Width
1.770 inches maximum
Fragility Factor
moderately rugged
Pole Quantity
2
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
4 clip
Storage Type
general purpose warehouse
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
magnetic all locations
Trip Release Characteristic
time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
between pole one and two
Internal Trip Release Configuration
series trip all locations
Trip Delay Time In Seconds Per Rated Continuous Current
10.000 minimum at 200 pct and 75.000 maximum at 200 pct all locations
Inclosure Protection Type For Which Designed
dustproof
Frequency In Hertz
50.0 or 60.0 all locations
Material
plastic case
Terminal Type And Quantity
4 tab, solder lug

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
203-22-1-66-103-F-1-23 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-286-2805?
The FSCG of the NSN 5925-01-286-2805 is 5925
Does the NSN 5925-01-286-2805 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-286-2805 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-286-2805 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-286-2805 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-286-2805 was assigned to the Federal Catalog?
It was assigned 37 years ago, on Thu, Sep 29, 1988

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

595-7067876-4
5307-01-543-9370
Continuous Thread Stud
595-7067876-42
3120-01-497-6408
Sleeve Bushing
595-7067876-43
2815-01-640-9872
Cartridge Fire Trip
595-7067876-43L1
2815-01-640-9872
Cartridge Fire Trip
595-7067876-45
3120-01-497-6407
Sleeve Bushing
595-7067876-4A
5307-01-543-9370
Continuous Thread Stud
595-7067876-4AL1
5307-01-543-9370
Continuous Thread Stud
595-7067876-4L1
5307-01-543-9370
Continuous Thread Stud
595-7067876-56
3040-01-497-9156
Control Cam
595-7067876-57
3040-01-644-3048
Rigid Connecting Link
595-7067876-58
5340-01-644-4516
Interlock Rod
595-7067876-59
3040-01-644-4479
Rigid Connecting Link
595-7067876-60
3040-01-497-9159
Control Cam
595-7067876-61
5305-01-497-8587
Hexagon Head Cap Screw
595-7067876-62
5340-01-497-5816
Rod End Connector