1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-01-249-7545

5925-01-249-7545

Find complete technical information, availability, and procurement data for: 5925-01-249-7545

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-249-7545 to receive an up to date pricing and availability quote by email.

5925-01-249-7545
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-249-7545
Item Name Code
00136
Assigment Date
02/16/1987 (39 years ago)

"a device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes:circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller."

7.750 inches nominal center to center distance between terminals parallel to length, 3.187 inches nominal body height, 10.125 inches nominal body length, 4.125 inches nominal body width, multipole-single actuator type body style

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
multipole-single actuator type
Body Length
10.125 inches nominal
Body Width
4.125 inches nominal
Body Height
3.187 inches nominal
Center To Center Distance Between Terminals Parallel To Length
7.750 inches nominal
Center To Center Distance Between Terminals Parallel To Width
1.374 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
7.750 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.687 inches nominal
Fragility Factor
moderately rugged
Boss Height
2.313 inches nominal
Pole Quantity
3
Arc Quenching Method
air
Mounting Facility Type And Quantity
4 unthreaded hole
Storage Type
general purpose warehouse
Features Provided
adjustable trip release
Cubic Measure
133.107 cubic inches
Maximum Continuous Load Current Rating Per Pole
225.0 amperes ac and 225.0 amperes dc all locations
Operating Voltage Type And Rating Per Pole In Volts
600.0 ac and 250.0 dc all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
25000.0 ac and 10000.0 dc all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
magnetic all locations
Trip Release Characteristic
instantaneous all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Adjustable Trip Setting Current Range Per Pole In Amps
+600.0 to 1400.0 ac all locations
Internal Trip Release Configuration
series trip all locations
Frequency In Hertz
60.0 all locations
Material
plastic case
Terminal Type And Quantity
6 screw

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
TFC36225 Circuit Breaker
TFC36225LL Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-249-7545?
The FSCG of the NSN 5925-01-249-7545 is 5925
Does the NSN 5925-01-249-7545 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-249-7545 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-249-7545 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-249-7545 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-249-7545 was assigned to the Federal Catalog?
It was assigned 39 years ago, on Mon, Feb 16, 1987

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

M0066201210
6515-01-502-5651
Urethral Guide Wire
M0066201300
6515-01-502-5655
Ureteral Guide Wire
M0066301021
6515-01-348-8672
Urethral Guide Wire
M006630205B1
6515-01-631-0920
Ureteral Guide Wire
M006630206B1
6515-01-348-8672
Urethral Guide Wire
M0066802051
6515-01-631-0920
Ureteral Guide Wire
M00671-1
6130-01-563-8242
Static Power Inverter
M00671-2
6130-01-563-8233
Static Power Inverter
M0067101131
6515-01-680-3043
Ureteroscopy Inflation Device
M0067301251
6515-01-482-7509
Bladder Evacuator
M0067318
5895-01-599-7390
Communications Modem
M0068404120
6515-01-471-6341
Stone Lithot Basket
M006A0007-00
4820-01-376-4341
Directional Contr Body and Slide
M006A0032-00
5340-01-377-0913
Helical Compression Spring Seat
M006A0033-00
5365-01-375-2930
Sleeve Spacer