1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-01-231-1897

5925-01-231-1897

Find complete technical information, availability, and procurement data for: 5925-01-231-1897

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-231-1897 to receive an up to date pricing and availability quote by email.

5925-01-231-1897
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-231-1897
Item Name Code
00136
Assigment Date
04/24/1986 (40 years ago)

Any combination of items manufactured from packing material to predetermined dimensions, or any combination of nonmetallic molded or formed shapes (other than solid rubber or synthetic rubber rings having a square or rectangular cross section) specifically designed and manufactured for use as a seal. The assembly may include metal lantern rings, metal separators, and/or end or adapter rings.

1.969 inches minimum and 2.031 inches maximum body length, multipole-single actuator type body style, 2.265 inches maximum body width, 0.464 inches minimum and 0.526 inches maximum bushing length, 1.499 inches minimum and 1.561 inches maximum center to center distance between terminals parallel to length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
multipole-single actuator type
Bushing Length
0.464 inches minimum and 0.526 inches maximum
Body Length
1.969 inches minimum and 2.031 inches maximum
Body Width
2.265 inches maximum
Center To Center Distance Between Terminals Parallel To Length
1.499 inches minimum and 1.561 inches maximum
Center To Center Distance Between Terminals Parallel To Width
0.735 inches minimum and 0.765 inches maximum
Nonturn Device Radius
0.641 inches minimum and 0.671 inches maximum
Nonturn Device Length
0.115 inches minimum and 0.145 inches maximum
Nonturn Device Diameter
0.138 inches nominal
Switch Contact Arrangement
single pole, double throw
Fragility Factor
moderately rugged
Mounting Surface To Terminal End Distance
2.232 inches maximum
Pole Quantity
3
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
Storage Type
general purpose warehouse
Special Handling Feature
magnetic
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac first location
Maximum Continuous Load Current Rating Per Pole
30.0 amperes ac second location
Maximum Continuous Load Current Rating Per Pole
30.0 amperes ac third location
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
magnetic all locations
Trip Release Characteristic
time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole two
Auxiliary Switch Function And Quantity
1 alarm
Internal Trip Release Configuration
series trip all locations
Nominal Thread Size
0.500 inches
Switch Location And Position Designation
internal at pole one
Trip Delay Time In Seconds Per Rated Continuous Current
3.000 minimum at 200 pct and 20.000 maximum at 200 pct all locations
Inclosure Protection Type For Which Designed
fungus resistant
Switch Terminal Type
tab, solder lug
Switch Current Rating And Type In Amps
10.0 ac and 2.0 dc
Switch Voltage Rating And Type In Volts
250.0 ac and 50.0 dc
Frequency In Hertz
60.0 all locations
Material
plastic case
Test Data Document
"81349-mil-c-55629 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.)."
Thread Series Designator
un
Terminal Type And Quantity
6 tab w/screw
Specification/Standard Data
81349-mil-c-55629/22 government specification

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
M55629/22RMUMUM Circuit Breaker
MIL-C-55629/22 Circuit Breaker
MIL-PRF-55629/22 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-231-1897?
The FSCG of the NSN 5925-01-231-1897 is 5925
Does the NSN 5925-01-231-1897 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-231-1897 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-231-1897 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-231-1897 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-231-1897 was assigned to the Federal Catalog?
It was assigned 40 years ago, on Thu, Apr 24, 1986

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

RB16CE499R0B
5905-00-978-7531
Wire Wound Fixed Resistor
RB16CE499R0F
5905-00-815-3314
Wire Wound Fixed Resistor
RB16CE49R00B
5905-01-199-4175
Wire Wound Fixed Resistor
RB16CE49R30B
5905-01-199-4175
Wire Wound Fixed Resistor
RB16CE49R90B
5905-00-931-0325
Wire Wound Fixed Resistor
RB16CE49R90D
5905-00-926-8716
Wire Wound Fixed Resistor
RB16CE49R90F
5905-00-880-9723
Wire Wound Fixed Resistor
RB16CE4R120F
5905-01-265-9468
Wire Wound Fixed Resistor
RB16CE4R320F
5905-00-776-5866
Wire Wound Fixed Resistor
RB16CE4R420F
5905-00-710-1762
Wire Wound Fixed Resistor
RB16CE4R640F
5905-00-059-9871
Wire Wound Fixed Resistor
RB16CE4R990D
5905-01-265-7855
Wire Wound Fixed Resistor
RB16CE4R990F
5905-00-059-6319
Wire Wound Fixed Resistor
RB16CE50000B
5905-00-060-2021
Wire Wound Fixed Resistor
RB16CE50001B
5905-00-810-8116
Wire Wound Fixed Resistor