1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-01-228-2309

5925-01-228-2309

Find complete technical information, availability, and procurement data for: 5925-01-228-2309

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-228-2309 to receive an up to date pricing and availability quote by email.

5925-01-228-2309
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-228-2309
Item Name Code
00136
Assigment Date
03/16/1986 (40 years ago)

0.360 inches minimum and 0.380 inches maximum bushing length, 1.841 inches minimum and 1.903 inches maximum body width, multipole-single actuator type body style, 1.464 inches minimum and 1.526 inches maximum body length, 0.870 inches minimum and 0.880 inches maximum center to center distance between terminals parallel to length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
multipole-single actuator type
Bushing Length
0.360 inches minimum and 0.380 inches maximum
Body Length
1.464 inches minimum and 1.526 inches maximum
Body Width
1.841 inches minimum and 1.903 inches maximum
Center To Center Distance Between Terminals Parallel To Length
0.870 inches minimum and 0.880 inches maximum
Center To Center Distance Between Terminals Parallel To Width
0.620 inches minimum and 0.630 inches maximum
Fragility Factor
moderately rugged
Mounting Surface To Terminal End Distance
1.647 inches minimum and 1.709 inches maximum
Pole Quantity
4
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
Storage Type
general purpose warehouse
Thread Quantity Per Inch
32
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
magnetic-hydraulic all locations
Trip Release Characteristic
time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole two
Internal Trip Release Configuration
series trip all locations
Nominal Thread Size
0.375 inches
Trip Delay Time In Seconds Per Rated Continuous Current
1.000 minimum at 200 pct and 4.500 maximum at 200 pct all locations
Inclosure Protection Type For Which Designed
dustproof
Frequency In Hertz
400.0 all locations
Thread Series Designator
unef
Terminal Type And Quantity
6 wire hook

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
SM3333250AC4001 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-228-2309?
The FSCG of the NSN 5925-01-228-2309 is 5925
Does the NSN 5925-01-228-2309 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-228-2309 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-228-2309 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-228-2309 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-228-2309 was assigned to the Federal Catalog?
It was assigned 40 years ago, on Sun, Mar 16, 1986

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

12420232
5340-01-377-0342
Permanent Magnet
12420234
3040-01-384-1135
Line Actuating Cylinder Assembly
12420235
2920-01-388-5637
Electrical Terminal Block
12420236
2920-01-388-5639
Electrical Terminal Block
12420238
5340-01-420-7614
Mounting Bracket
12420239
5340-01-381-3871
Angle Bracket
1242023P1
5950-00-726-4058
Reactor
12420242
2510-01-387-5155
Fender Brace
12420242-001
2510-01-387-5112
Fender Brace
12420242-002
2510-01-387-5155
Fender Brace
12420243
2510-01-390-4461
Fender Brace
1242025P3
5950-00-728-0796
Reactor
12420260-004
5320-01-384-2944
Pin-Rivet Collar
12420261-006
5340-01-384-0540
Rod End Clevis
12420262-001
4730-01-446-2113
Pipe to Tube Straight Adapter