DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-219-2979 to receive an up to date pricing and availability quote by email.

5925-01-219-2979
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-219-2979
Item Name Code
00136
Assigment Date
10/24/1985 (40 years ago)

0.625 inches nominal bushing length, multipole-single actuator type body style, +0.4752 to 0.4787 inches thread pitch diameters, 2.250 inches nominal body width, 2.000 inches nominal body length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Thread Pitch Diameters
+0.4752 to 0.4787 inches
Body Style
multipole-single actuator type
Bushing Length
0.625 inches nominal
Body Length
2.000 inches nominal
Body Width
2.250 inches nominal
Center To Center Distance Between Terminals Parallel To Length
1.530 inches nominal
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
Nonturn Device Radius
0.656 inches nominal
Nonturn Device Length
0.130 inches nominal
Nonturn Device Diameter
0.151 inches minimum and 0.161 inches maximum
Fragility Factor
moderately rugged
Mounting Surface To Terminal End Distance
2.232 inches maximum
Pole Quantity
3
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
Storage Type
general purpose warehouse
Special Handling Feature
magnetic
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
25.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2100.0 ac all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
magnetic-hydraulic all locations
Trip Release Characteristic
time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole two
Internal Trip Release Configuration
series trip all locations
Nominal Thread Size
0.500 inches
Trip Delay Time In Seconds Per Rated Continuous Current
12.000 minimum at 200 pct and 120.000 maximum at 200 pct all locations
Inclosure Protection Type For Which Designed
moisture resistant and salt spray proof and shock resistant and vibration resistant
Unpackaged Unit Weight
9.000 ounces nominal
Frequency In Hertz
400.0 all locations
Material
plastic case
Thread Series Designator
un
Terminal Type And Quantity
6 tab w/screw

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
APGN-666-1-43-253 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-219-2979?
The FSCG of the NSN 5925-01-219-2979 is 5925
Does the NSN 5925-01-219-2979 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-219-2979 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-219-2979 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-219-2979 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-219-2979 was assigned to the Federal Catalog?
It was assigned 40 years ago, on Thu, Oct 24, 1985

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

SW618-017
5930-00-048-6771
Rotary Switch
SW618-019
5930-00-039-8823
Rotary Switch
SW618-020
5930-00-581-6851
Rotary Switch
SW618-022
5930-01-026-8585
Rotary Switch
SW618-025
5930-00-274-0014
Rotary Switch
SW618-026
5930-00-114-9931
Rotary Switch
SW618-035
5930-00-203-5819
Rotary Switch
SW618-036
5930-00-208-4687
Rotary Switch
SW618-038
5930-01-018-4592
Rotary Switch
SW618-041
5930-00-114-5497
Rotary Switch
SW618-056
5930-00-308-7500
Rotary Switch
SW618-17
5930-00-905-2832
Push Switch
SW618-24
5930-00-004-6008
Rotary Switch
SW618-311
5930-01-042-1915
Rotary Switch
SW618-312
5930-01-041-6490
Rotary Switch