DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-138-4954 to receive an up to date pricing and availability quote by email.

5925-01-138-4954
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-138-4954
Item Name Code
00136
Assigment Date
09/15/1982 (43 years ago)

0.178 inches nominal mounting slot width, 1.026 inches nominal body width, 5.800 inches nominal body length, single pole type body style, 2.828 inches nominal body height

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Mounting Slot Width
0.178 inches nominal
Body Length
5.800 inches nominal
Body Width
1.026 inches nominal
Body Height
2.828 inches nominal
Center To Center Distance Between Terminals Parallel To Length
4.781 inches nominal
Unthreaded Mounting Hole Diameter
0.164 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.750 inches nominal
Fragility Factor
moderately rugged
Pole Quantity
1
Arc Quenching Method
air
Mounting Facility Type And Quantity
2 threaded hole and 1 unthreaded hole and 1 slot
Storage Type
general purpose warehouse
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
100.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
125.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 dc single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic-hydraulic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
140.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
12.000 minimum at 200 pct and 40.000 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
2 threaded stud

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
CD1-B3-DU-100-12 Circuit Breaker
CD1-B3-DU-100-125VDC-1 Circuit Breaker
CD1-B3DUW-100-125DC-1 Circuit Breaker
SC-D-691338-10 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-138-4954?
The FSCG of the NSN 5925-01-138-4954 is 5925
Does the NSN 5925-01-138-4954 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-138-4954 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-138-4954 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-138-4954 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-138-4954 was assigned to the Federal Catalog?
It was assigned 43 years ago, on Wed, Sep 15, 1982

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

3202304000
4320-01-120-3408
Pump Rotor
3202304KAD
5995-01-586-3408
E Special Purpose Cable Assembly
3202305-001
5962-01-217-1430
Digital Microcircuit
3202306
7610-01-561-2139
Book
3202306-1
5340-01-519-3777
Electronic Equipmen Hardware Kit
3202306-100
6150-01-562-7608
Electrical Cable Assembly Set
3202306-16
5895-01-536-2204
Electronic Equi Installation Kit
3202306-6
5995-01-517-6157
Electrical Cable Assembly Set
320230C1
4720-00-758-9140
Metallic Hose
3202310
5307-01-062-3142
Stud
3202311
5995-01-601-3375
E Special Purpose Cable Assembly
3202312
5995-01-601-3374
E Special Purpose Cable Assembly
3202312-AB120
5995-01-613-9911
E Special Purpose Cable Assembly
3202312-AB360
5995-01-569-3935
E Special Purpose Cable Assembly
3202312-HH128 REV.A
5995-01-558-4522
E Special Purpose Cable Assembly