1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-01-137-5668

5925-01-137-5668

Find complete technical information, availability, and procurement data for: 5925-01-137-5668

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-137-5668 to receive an up to date pricing and availability quote by email.

5925-01-137-5668
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-137-5668
Item Name Code
00136
Assigment Date
08/29/1982 (43 years ago)

A switch which is actuated by changes in pressure of any gas or liquid or by changes in a vacuum acting upon its sensing element. Excludes:baroswitch; switch,pressure-thermostatic; and switch,sensitive.

3.188 inches nominal body height, multipole-single actuator type body style, 10.125 inches nominal body length, 4.125 inches nominal body width, 7.750 inches nominal center to center distance between terminals parallel to length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
multipole-single actuator type
Body Length
10.125 inches nominal
Body Width
4.125 inches nominal
Body Height
3.188 inches nominal
Center To Center Distance Between Terminals Parallel To Length
7.750 inches nominal
Center To Center Distance Between Terminals Parallel To Width
1.375 inches nominal
Unthreaded Mounting Hole Diameter
0.190 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
7.750 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.375 inches nominal
Fragility Factor
moderately rugged
Boss Height
0.219 inches nominal
Pole Quantity
3
Mounting Facility Type And Quantity
4 unthreaded hole
Storage Type
general purpose warehouse
Maximum Continuous Load Current Rating Per Pole
200.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
600.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
22000.0 ac all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
thermal-magnetic all locations
Trip Release Characteristic
instantaneous and time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole two
Trip Delay Time In Seconds Per Rated Continuous Current
0.250 maximum at 200 pct all locations
Inclosure Protection Type For Which Designed
general purpose
Trip Release Ambient Temp Rating
40.0 celsius nominal all locations
Frequency In Hertz
60.0 all locations
Material
plastic case
Terminal Type And Quantity
6 compression

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
TFK236200WL Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-137-5668?
The FSCG of the NSN 5925-01-137-5668 is 5925
Does the NSN 5925-01-137-5668 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-137-5668 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-137-5668 contain precious materials?
Precious metal content is unknown
Does NSN 5925-01-137-5668 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-137-5668 was assigned to the Federal Catalog?
It was assigned 43 years ago, on Sun, Aug 29, 1982

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

LINO FLEX 1W
6750-00-177-5147
Photographic Film
LINO-WRIT 5B
6750-00-778-0399
Photographic Paper
LINO-WRIT 5W
6750-00-485-9897
Photographic Paper
LINUX 7.0
7030-01-549-3832
Software Kit
LINUX ES VERSION2.1 STANDARD
7030-01-523-6075
Software Kit
LINUX WS
7030-01-578-6619
Software Kit
LINX 3400
7035-01-682-9628
Signal Data Converter-Storer
LINX 8X8SP
7025-01-691-3274
Matrix Data Storage
LINX 900
7025-01-596-8913
Data Transfer Interface Unit
LINX1800
5930-01-696-0697
Electronic Switch
LIO-CMTRN=71 SIZE L
6930-01-717-7763
Cbrn Contaminants Prot Coveralls
LIO-CMTRN=71 SIZE M
6930-01-717-7756
Cbrn Contaminants Prot Coveralls
LIO-CMTRN=71 SIZE S
6930-01-717-7765
Cbrn Contaminants Prot Coveralls
LIO-CMTRN=71 SIZE XL
6930-01-717-7742
Cbrn Contaminants Prot Coveralls
LIONHEART 3
6625-01-497-7918
Multi-Parameter Simulator