DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-137-0672 to receive an up to date pricing and availability quote by email.

5925-01-137-0672
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-137-0672
Item Name Code
00136
Assigment Date
08/20/1982 (43 years ago)

2.250 inches nominal body width, 0.750 inches nominal center to center distance between terminals parallel to width, 2.500 inches nominal body length, 1.938 inches nominal center to center distance between terminals parallel to length, multipole-multiple actuator type body style

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
multipole-multiple actuator type
Body Length
2.500 inches nominal
Body Width
2.250 inches nominal
Center To Center Distance Between Terminals Parallel To Length
1.938 inches nominal
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.062 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches nominal
Boss Height
0.140 inches nominal
Mounting Surface To Terminal End Distance
2.474 inches nominal
Pole Quantity
3
Mounting Facility Type And Quantity
6 threaded hole
Storage Type
general purpose warehouse
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
magnetic-hydraulic all locations
Trip Release Characteristic
time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
3 toggle
Actuator Function
trip-reset
Actuator Position Designation
at each pole
External Actuator Linkage Arrangement
one, two, and three linked
Internal Trip Release Configuration
series trip all locations
Nominal Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 minimum at 200 pct and 20.000 maximum at 200 pct all locations
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
Frequency In Hertz
50.0 or 60.0 all locations
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
6 threaded stud

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
56F836 Circuit Breaker
W93X1-1-2-20 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-137-0672?
The FSCG of the NSN 5925-01-137-0672 is 5925
Does the NSN 5925-01-137-0672 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-137-0672 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-137-0672 contain precious materials?
Precious metal content is unknown
Does NSN 5925-01-137-0672 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-137-0672 was assigned to the Federal Catalog?
It was assigned 43 years ago, on Fri, Aug 20, 1982

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

72P231600-7
6625-00-823-5032
Voltmeter
72P231601-1
6625-00-823-5325
Ammeter
72P231601-11
6625-00-889-1624
Ammeter
72P231601-12
6625-00-063-5268
Ammeter
72P231601-3
6625-00-649-3660
Ammeter
72P231601-4
6625-00-855-1508
Ammeter
72P231601-5
6625-00-843-0774
Ammeter
72P231601-6
6625-00-855-1513
Ammeter
72P231601-9
6625-00-855-1512
Ammeter
72P236668
6645-00-904-2754
Time Totalizing Meter
72P237282-21-11
6625-00-263-7816
Arbitrary Scale Meter
72P238295
5841-00-162-2844
Radar Target Indicator
72P238295-1
5841-00-162-2844
Radar Target Indicator
72P240000-1003
1290-01-471-2938
Fire Control Interface Unit
72P240001-1003
1290-01-471-3071
Fire Control Equ Operations Unit