1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-01-130-8421

5925-01-130-8421

Find complete technical information, availability, and procurement data for: 5925-01-130-8421

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-130-8421 to receive an up to date pricing and availability quote by email.

5925-01-130-8421
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-130-8421
Item Name Code
00136
Assigment Date
04/29/1982 (44 years ago)

2.060 inches nominal distance between centerlines of mounting facilities parallel to body length, 0.750 inches nominal body width, 2.490 inches nominal body length, single pole type body style, 1.938 inches nominal center to center distance between terminals parallel to length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Body Length
2.490 inches nominal
Body Width
0.750 inches nominal
Center To Center Distance Between Terminals Parallel To Length
1.938 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.060 inches nominal
Boss Height
0.150 inches nominal
Mounting Surface To Terminal End Distance
2.471 inches maximum
Pole Quantity
1
Mounting Facility Type And Quantity
2 threaded hole
Storage Type
general purpose warehouse
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
500.0 milliamperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 dc single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic-hydraulic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
0.175 minimum at 200 pct and 0.500 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
shockproof and vibrationproof
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
2 threaded stud

Replaces National Stock Numbers

Below is a list of NSNs that have been officially superseded by this NSN:

NSN Name Date
5925-01-226-9300 No Name Available 01/01/1990

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
37661219-928 Circuit Breaker
926960-31 Circuit Breaker
92696031 Circuit Breaker
AM1-2175-9 Circuit Breaker
UPL1-138-31 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-130-8421?
The FSCG of the NSN 5925-01-130-8421 is 5925
Does the NSN 5925-01-130-8421 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-130-8421 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-130-8421 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-130-8421 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-130-8421 was assigned to the Federal Catalog?
It was assigned 44 years ago, on Thu, Apr 29, 1982

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

6151-1
5306-01-671-0216
Machine Bolt
6151-106-W5R-102M
5910-00-080-4022
Ceramic Dielectr Fixed Capacitor
6151-106-W5R-332M
5910-00-061-7109
Ceramic Dielectr Fixed Capacitor
6151-106W5R502M
5910-00-010-8715
Ceramic Dielectr Fixed Capacitor
6151-107W5R103M
5910-00-061-5422
Ceramic Dielectr Fixed Capacitor
6151-107W5R203M
5910-00-080-4020
Ceramic Dielectr Fixed Capacitor
6151-108-W5R-104M
5910-00-984-1086
Ceramic Dielectr Fixed Capacitor
6151-108-W5R-503M
5910-00-080-4019
Ceramic Dielectr Fixed Capacitor
6151-11-5710
5330-01-537-1373
Gasket
6151-115710
5330-01-537-1373
Gasket
6151-120-3
5930-00-988-1953
Rotary Switch
6151-1C
5340-00-111-7503
Spring Tension Clip
6151 7049 80
5130-01-654-8518
Sander,disk,electric,portable
6151-9025
6625-01-308-8052
Digital Reado Electronic Counter
6151-A
4820-01-297-0149
Restrictor Check Valve