DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for part AP114-6092-1 to receive an up to date pricing and availability quote by email.
"a device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes:circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller."
1.987 inches maximum body width, 0.875 inches nominal center to center distance between terminals parallel to length, multipole-single actuator type body style, 1.562 inches maximum body length, 0.380 inches maximum bushing length
Product Characteristics
Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.
- Body Style
- multipole-single actuator type
- Bushing Length
- 0.380 inches maximum
- Body Length
- 1.562 inches maximum
- Body Width
- 1.987 inches maximum
- Center To Center Distance Between Terminals Parallel To Length
- 0.875 inches nominal
- Center To Center Distance Between Terminals Parallel To Width
- 0.625 inches nominal
- Fragility Factor
- moderately rugged
- Mounting Surface To Terminal End Distance
- 1.780 inches maximum
- Pole Quantity
- 3
- Mounting Facility Type And Quantity
- 2 threaded bushing w/panel seal
- Storage Type
- general purpose warehouse
- Special Handling Feature
- magnetic
- Thread Quantity Per Inch
- 32
- Maximum Continuous Load Current Rating Per Pole
- 12.0 amperes ac first location
- Maximum Continuous Load Current Rating Per Pole
- 12.0 amperes ac second location
- Operating Voltage Type And Rating Per Pole In Volts
- 12.0 dc third location
- Operating Voltage Type And Rating Per Pole In Volts
- 240.0 ac first location
- Operating Voltage Type And Rating Per Pole In Volts
- 240.0 ac second location
- Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
- 300.0 ac first location
- Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
- 300.0 ac second location
- Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
- 500.0 dc third location
- Circuit Protection Type
- overcurrent all locations
- Trip Release Method
- magnetic-hydraulic all locations
- Trip Release Characteristic
- instantaneous third location
- Trip Release Characteristic
- time delay first location
- Trip Release Characteristic
- time delay second location
- Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
- 135.0 all locations
- Reset Method
- manual
- Main Contact Tripping Mechanism Type
- trip free
- Manual Actuator Type And Quantity
- 1 toggle
- Actuator Function
- trip-reset
- Actuator Position Designation
- at pole two
- Internal Trip Release Configuration
- relay trip third location
- Internal Trip Release Configuration
- series trip first location
- Internal Trip Release Configuration
- series trip second location
- Nominal Thread Size
- 0.375 inches
- Trip Delay Time In Seconds Per Rated Continuous Current
- 0.500 minimum at 200 pct and 9.000 maximum at 200 pct first location
- Trip Delay Time In Seconds Per Rated Continuous Current
- 0.500 minimum at 200 pct and 9.000 maximum at 200 pct second location
- Inclosure Protection Type For Which Designed
- hermetically sealed and shockproof and vibrationproof
- Unpackaged Unit Weight
- 5.400 ounces nominal
- Frequency In Hertz
- 400.0 first location
- Frequency In Hertz
- 400.0 second location
- Thread Series Designator
- unef
- Terminal Type And Quantity
- 6 wire hook
Related Parts
This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:
| Part Number | Name |
|---|---|
| 1857432 | Circuit Breaker |
| AP114-6092-1 | Circuit Breaker |
FAQs
Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.
What is the FSCG of the NSN 5925-01-129-6220?
Does the NSN 5925-01-129-6220 have a Schedule B code assigned?
Does NSN 5925-01-129-6220 require demilitarization?
Does NSN 5925-01-129-6220 contain precious materials?
Does NSN 5925-01-129-6220 contain hazardous materials?
When the NSN 5925-01-129-6220 was assigned to the Federal Catalog?
Professional Distribution
Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.
- ITAR Registered
- DDTC Registered
- HAZMAT Certified
- AS9120 Quality Standards
- 100% Quality Inspections
You May Also Like
Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.
Pricing
Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information: