1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-01-125-5795

5925-01-125-5795

Find complete technical information, availability, and procurement data for: 5925-01-125-5795

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-125-5795 to receive an up to date pricing and availability quote by email.

5925-01-125-5795
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-125-5795
Item Name Code
00136
Assigment Date
01/29/1982 (44 years ago)

3.709 inches minimum and 3.729 inches maximum body length, single pole type body style, 2.740 inches minimum and 2.760 inches maximum distance between centerlines of mounting facilities parallel to body length, 3.053 inches minimum and 3.073 inches maximum center to center distance between terminals parallel to length, 0.980 inches minimum and 1.000 inches maximum body width

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Body Length
3.709 inches minimum and 3.729 inches maximum
Body Width
0.980 inches minimum and 1.000 inches maximum
Center To Center Distance Between Terminals Parallel To Length
3.053 inches minimum and 3.073 inches maximum
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.740 inches minimum and 2.760 inches maximum
Fragility Factor
moderately rugged
Boss Height
0.146 inches minimum and 0.166 inches maximum
Mounting Surface To Terminal End Distance
2.229 inches minimum and 2.249 inches maximum
Pole Quantity
1
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
2 threaded hole
Storage Type
general purpose warehouse
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
30.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
28.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 dc single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic-hydraulic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
130.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
2.200 minimum at 200 pct and 7.500 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
fungus resistant
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
2 threaded stud

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
AM1516MG3-30-28VDCC2 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-125-5795?
The FSCG of the NSN 5925-01-125-5795 is 5925
Does the NSN 5925-01-125-5795 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-125-5795 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-125-5795 contain precious materials?
Precious metal content is unknown
Does NSN 5925-01-125-5795 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-125-5795 was assigned to the Federal Catalog?
It was assigned 44 years ago, on Fri, Jan 29, 1982

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

PR-14
5130-00-177-6876
Pneumatic Blind Riveter
PR-14-2-100-1/4-6-E
5905-01-430-8746
Thermal Resistor
PR-14-2-100-1/4-9-E
5905-01-392-6254
Thermal Resistor
PR-14-3-100-1/4-6
5905-01-716-4062
Thermal Resistor
PR-14-3-400-1/4-5 1/2-E
5905-01-263-7857
Thermal Resistor
PR-14-S
7025-01-551-1157
Automatic Data Pr Interface Unit
PR-140-10-FG9
5940-01-102-8459
Stud Terminal
PR-1403-G A-1/2
8030-01-350-7161
Sealing Compound
PR-1403-G A-2
8030-01-201-5534
Sealing Compound
PR-1403-G B-1/2
8030-01-345-2108
Sealing Compound
PR-1403-G B-2
6850-01-104-5396
Chemical Sealer
PR-1403-G B-2 654 SEMKIT
8030-01-353-7148
Sealing Compound
PR-1405-G
6850-01-395-0898
Chemical Sealer
PR-1405G
8030-01-692-4592
Sealing Compound
PR-1405Q
8030-01-692-4592
Sealing Compound