1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-01-125-4870

5925-01-125-4870

Find complete technical information, availability, and procurement data for: 5925-01-125-4870

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-125-4870 to receive an up to date pricing and availability quote by email.

5925-01-125-4870
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-125-4870
Item Name Code
00136
Assigment Date
01/28/1982 (44 years ago)

0.250 inches nominal bushing length, 0.750 inches nominal body length, single pole type body style, 0.562 inches nominal body width, 0.703 inches nominal center to center distance between terminals parallel to length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Bushing Length
0.250 inches nominal
Body Length
0.750 inches nominal
Body Width
0.562 inches nominal
Center To Center Distance Between Terminals Parallel To Length
0.703 inches nominal
Fragility Factor
moderately rugged
Mounting Surface To Terminal End Distance
1.707 inches nominal
Pole Quantity
1
Arc Quenching Method
air
Mounting Facility Type And Quantity
1 threaded bushing
Storage Type
general purpose warehouse
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
2.0 amperes ac and 2.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac and 28.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
800.0 ac and 2000.0 dc single location
Circuit Protection Type
overcurrent single location
Trip Release Method
thermal single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
145.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 push-pull
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.469 inches
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 minimum at 200 pct and 20.000 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
corrosion resistant and sand resistant
Trip Release Ambient Temp Rating
25.0 celsius nominal single location
Special Features
ampere marked on actuator
Frequency In Hertz
400.0 single location
Material
plastic case
Thread Series Designator
uns
Terminal Type And Quantity
2 tab w/screw

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
10484184 Circuit Breaker
7274-11-2 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-125-4870?
The FSCG of the NSN 5925-01-125-4870 is 5925
Does the NSN 5925-01-125-4870 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-125-4870 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-125-4870 contain precious materials?
Precious metal content is unknown
Does NSN 5925-01-125-4870 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-125-4870 was assigned to the Federal Catalog?
It was assigned 44 years ago, on Thu, Jan 28, 1982

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

MX100-24
6145-01-680-6450
Electrical Special Purpose Cable
MX100-E-1-D/S13
5998-01-626-2772
Circuit Card Assembly
MX1000
5805-01-455-3318
Audio Signal Scrambler
MX10058TT
6625-01-063-0091
Printe Test Adapter
MX10059TT
6625-01-063-0090
Powers Test Adapter
MX100F-2SA
6680-01-727-8483
Ultr Fluid Flow Indicating Meter
MX100P-24
6145-01-661-4594
Electrical Special Purpose Cable
MX100Q-24
6145-01-648-1491
Electrical Special Purpose Cable
MX101060-1600
5855-01-601-5022
Night Vision Image Intensifier
MX10130B/UV
5855-01-228-0942
Night Vis Image Intensifier Tube
MX10160B
5855-01-391-7077
Night Vision Image Intensifier
MX10166/U
6625-01-278-1473
Test Shield
MX1019U
5985-00-643-3172
Waveguide Probe
MX101AS-ML
4240-01-641-4533
Ind Spectacles Lens
MX101U
4010-00-537-3772
Guy