DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-112-4404 to receive an up to date pricing and availability quote by email.

5925-01-112-4404
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-112-4404
Item Name Code
00136
Assigment Date
05/06/1981 (45 years ago)

1.655 inches minimum and 1.665 inches maximum distance between centerlines of mounting facilities parallel to body length, 1.985 inches minimum and 2.015 inches maximum body length, 0.745 inches minimum and 0.755 inches maximum body width, 1.555 inches minimum and 1.565 inches maximum center to center distance between terminals parallel to length, single pole type body style

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Body Length
1.985 inches minimum and 2.015 inches maximum
Body Width
0.745 inches minimum and 0.755 inches maximum
Center To Center Distance Between Terminals Parallel To Length
1.555 inches minimum and 1.565 inches maximum
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.655 inches minimum and 1.665 inches maximum
Fragility Factor
moderately rugged
Boss Height
0.125 inches minimum and 0.135 inches maximum
Mounting Surface To Terminal End Distance
1.875 inches minimum and 1.885 inches maximum
Pole Quantity
1
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
2 threaded hole
Storage Type
general purpose warehouse
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
10.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
65.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 dc single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic-hydraulic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
0.900 minimum at 200 pct and 12.000 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
dustproof
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
2 threaded stud

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
JA1-B3-10-2 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-112-4404?
The FSCG of the NSN 5925-01-112-4404 is 5925
Does the NSN 5925-01-112-4404 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-112-4404 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-112-4404 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-112-4404 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-112-4404 was assigned to the Federal Catalog?
It was assigned 45 years ago, on Wed, May 6, 1981

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

JSI-0405-04
5365-01-581-2991
Tapered Bushing
JSI-0405-06
3120-01-614-5473
Sleeve Bearing
JSI-12/J72
6110-01-456-0725
Power Distribution Panel
JSI-12/J9
6110-01-585-9175
Electrical-Electro Control Panel
JSI-20
5895-01-496-4566
Communication Patching Panel
JSI-20/J13-50
5935-00-463-2610
Electrical Connector Assembly
JSI-24W
5998-00-583-8617
Electrical Patchboard
JSI-28/J3
5895-01-425-1136
Communication Patching Panel
JSI-28W/J9
5895-01-345-8807
Communication Patching Panel
JSI-32
5975-01-019-0463
Fanning Strip
JSI-32/J8
5895-01-032-5513
Communication Patching Panel
JSI-32A/J14HT-50
5985-01-358-5095
Antenna Patching Panel
JSI-32S
5895-01-540-8746
Communication Patching Panel
JSI-32S/J3
5895-01-575-7353
Communication Patching Panel
JSI-3F
5307-01-682-0899
Plain Stud