5925-01-085-9022

Find complete technical information, availability, and procurement data for: 5925-01-085-9022

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-085-9022 to receive an up to date pricing and availability quote by email.

5925-01-085-9022
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-085-9022
Item Name Code
00136
Assigment Date
11/18/1979 (46 years ago)

5.768 inches minimum and 5.832 inches maximum body length, 3.515 inches minimum and 3.579 inches maximum center to center distance between terminals parallel to length, 0.164 inches nominal mounting slot width, multipole-multiple actuator type body style, 3.046 inches minimum and 3.110 inches maximum body width

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
multipole-multiple actuator type
Mounting Slot Width
0.164 inches nominal
Body Length
5.768 inches minimum and 5.832 inches maximum
Body Width
3.046 inches minimum and 3.110 inches maximum
Center To Center Distance Between Terminals Parallel To Length
3.515 inches minimum and 3.579 inches maximum
Center To Center Distance Between Terminals Parallel To Width
0.994 inches minimum and 1.058 inches maximum
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.718 inches minimum and 2.782 inches maximum
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.994 inches minimum and 1.058 inches maximum
Fragility Factor
moderately rugged
Boss Height
0.187 inches minimum and 0.251 inches maximum
Mounting Surface To Terminal End Distance
3.172 inches minimum and 3.296 inches maximum
Pole Quantity
3
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
6 threaded hole and 6 slot
Storage Type
general purpose warehouse
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
100.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
480.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
magnetic-hydraulic all locations
Trip Release Characteristic
time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
3 toggle
Actuator Function
trip-reset
Actuator Position Designation
at each pole
External Actuator Linkage Arrangement
one, two, and three linked
Internal Trip Release Configuration
series trip all locations
Nominal Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
30.000 minimum at 200 pct and 100.000 maximum at 200 pct all locations
Inclosure Protection Type For Which Designed
dustproof
Frequency In Hertz
60.0 all locations
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
6 threaded stud

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
CD3-A3-100-480-9 Circuit Breaker
CD3-A3-40-100-480-9 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-085-9022?
The FSCG of the NSN 5925-01-085-9022 is 5925
Does the NSN 5925-01-085-9022 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-085-9022 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-085-9022 contain precious materials?
Precious metal content is unknown
Does NSN 5925-01-085-9022 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-085-9022 was assigned to the Federal Catalog?
It was assigned 46 years ago, on Sun, Nov 18, 1979

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

14020-111
1680-01-496-7262
Aircraft Ejection Seat
14020-2
1650-01-450-7103
Four Selector Valve
14020-204-000
5340-01-321-0517
Butt Hinge
14020-300
6640-00-753-2057
Laboratory Beaker
14020 353MM 2IN
4820-01-223-5119
Valve Seat
14020 36011
4820-01-223-5119
Valve Seat
14020-4400-01
7010-01-700-7683
Digital Computer System
14020-4400-04
7021-01-700-8300
Digital Computer
14020-6003-01
6130-01-480-2107
Power Supply
14020-6016-01
5995-01-657-2317
Electrical Power Cable Assembly
14020-H-33011
4820-01-136-3836
Valve Seat
14020-S1
6515-01-580-6818
Hypodermic Syringe
140200
5120-00-595-9552
Retaining Ring Pliers
140200-000
3040-00-289-8429
Spur Gearshaft
140200-01-01
6605-00-717-4027
Magnetic Electronic Compensator