1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-01-081-3689

5925-01-081-3689

Find complete technical information, availability, and procurement data for: 5925-01-081-3689

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-081-3689 to receive an up to date pricing and availability quote by email.

5925-01-081-3689
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-081-3689
Item Name Code
00136
Assigment Date
08/12/1979 (46 years ago)

"a device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes:circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller."

2.000 inches nominal body length, 1.660 inches nominal center to center distance between terminals parallel to length, 1.500 inches nominal body width, 0.750 inches nominal center to center distance between terminals parallel to width, multipole-multiple actuator type body style

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
multipole-multiple actuator type
Body Length
2.000 inches nominal
Body Width
1.500 inches nominal
Center To Center Distance Between Terminals Parallel To Length
1.660 inches nominal
Center To Center Distance Between Terminals Parallel To Width
0.750 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.660 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches nominal
Boss Height
0.130 inches nominal
Mounting Surface To Terminal End Distance
1.845 inches nominal
Pole Quantity
2
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
4 threaded hole
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
1.0 amperes ac first location
Maximum Continuous Load Current Rating Per Pole
3.0 amperes ac second location
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
magnetic-hydraulic all locations
Trip Release Characteristic
time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
2 toggle
Actuator Function
trip-reset
Actuator Position Designation
at each pole
External Actuator Linkage Arrangement
one and two linked
Internal Trip Release Configuration
relay trip first location
Internal Trip Release Configuration
series trip second location
Nominal Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
0.150 minimum at 200 pct and 1.500 maximum at 200 pct all locations
Inclosure Protection Type For Which Designed
moisture resistant
Unpackaged Unit Weight
0.312 pounds nominal
Frequency In Hertz
60.0 all locations
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
6 quick disconnect, male

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
127-0270 Circuit Breaker
127-0388 Circuit Breaker
UPGH-14-725-2 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-081-3689?
The FSCG of the NSN 5925-01-081-3689 is 5925
Does the NSN 5925-01-081-3689 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-081-3689 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-081-3689 contain precious materials?
Precious metal content is unknown
Does NSN 5925-01-081-3689 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-081-3689 was assigned to the Federal Catalog?
It was assigned 46 years ago, on Sun, Aug 12, 1979

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

77C5208A0023
4930-00-705-9547
Drum Unloading Manifold
77C5208A0024
4730-00-705-9556
Quick Disconnect Wye
77C5208A0025
4930-00-106-8673
Fuel Meter Assembly
77C5208A0031
6680-01-294-3489
Flow Rate Indicating Meter
77C5208A0032
3835-01-414-1874
Displacement and Evacuation Kit,
77C5208A0035
4930-00-106-8672
Skid Mounted Meter Assembly
77C5208A0036
4820-00-106-8671
Drum Unloading Valve
77C5208A0037
4820-00-075-2404
Gate Valve
77C5208A0038
4730-00-705-9555
Quick Disconnect Wye
77C5208A0044
6680-00-110-5779
Rate of Flow Indicator
77C5208A0045
4930-00-106-8678
Fuel Pres Regulator
77C5208A0046
3835-01-414-1870
Displacement and Evacuation Kit,
77C5208A0048
4930-00-106-8674
Fuel and Oil Servicing Nozzle
77C5208A0065
4930-01-103-7609
Trail Pump Assembly
77C5209A0000
4930-01-094-0026
Supply Point Fuel System