1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-01-075-3806

5925-01-075-3806

Find complete technical information, availability, and procurement data for: 5925-01-075-3806

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-075-3806 to receive an up to date pricing and availability quote by email.

5925-01-075-3806
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-075-3806
Item Name Code
00136
Assigment Date
04/20/1979 (47 years ago)

"a device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes:circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller."

1.660 inches minimum and 1.960 inches maximum center to center distance between terminals parallel to length, 2.046 inches minimum and 2.078 inches maximum distance between centerlines of mounting facilities parallel to body length, single pole type body style, 0.730 inches minimum and 0.780 inches maximum body width, 2.510 inches maximum body length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Body Length
2.510 inches maximum
Body Width
0.730 inches minimum and 0.780 inches maximum
Center To Center Distance Between Terminals Parallel To Length
1.660 inches minimum and 1.960 inches maximum
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.046 inches minimum and 2.078 inches maximum
Switch Contact Arrangement
single pole, double throw
Boss Height
0.109 inches minimum and 0.171 inches maximum
Mounting Surface To Terminal End Distance
2.800 inches maximum
Pole Quantity
1
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
2 threaded hole
Storage Type
general purpose warehouse
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
1.0 amperes ac single location
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Auxiliary Switch Function And Quantity
1 alarm
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.138 inches
Switch Location And Position Designation
internal at pole one
Trip Delay Time In Seconds Per Rated Continuous Current
2.100 minimum at 200 pct and 20.000 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
shock resistant and vibration resistant
Switch Terminal Type
tab, solder lug
Switch Current Rating And Type In Amps
10.0 ac and 2.0 dc
Switch Voltage Rating And Type In Volts
250.0 ac and 50.0 dc
Frequency In Hertz
400.0 single location
Material
plastic case
Test Data Document
"81349-mil-c-55629 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.)."
Thread Series Designator
unc
Terminal Type And Quantity
2 threaded stud
Specification/Standard Data
81349-mil-c-55629/2 government specification

Replaces National Stock Numbers

Below is a list of NSNs that have been officially superseded by this NSN:

NSN Name Date
5925-00-192-5618 No Name Available 06/01/1992
5925-00-978-4963 No Name Available 05/10/2012

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
70-132-33MG6 Circuit Breaker
711570-246 Circuit Breaker
M55629/2-019 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-075-3806?
The FSCG of the NSN 5925-01-075-3806 is 5925
Does the NSN 5925-01-075-3806 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-075-3806 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-075-3806 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-075-3806 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-075-3806 was assigned to the Federal Catalog?
It was assigned 47 years ago, on Fri, Apr 20, 1979

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

83-14903
6680-01-214-0260
Electronic Tachometer
83-14904
6625-01-210-6519
Voltmeter
83-14905
6625-01-210-7310
Power Factor Meter
83-14906
6625-01-210-6584
Ammeter
83-14907
6625-01-210-6520
Voltmeter
83-14908
6625-01-210-7311
Electrical Frequency Meter
83-14909
6680-01-210-7299
Liquid Quantity Indicator
83-14910
6625-01-214-0266
Ampere-Hour Meter
83-14911
6625-01-210-6585
Ammeter
83-14912
6625-01-210-6583
Voltmeter
83-14920
5310-01-226-4806
Flat Washer
83-14921
3120-01-226-4804
Thrust Washer Bearing
83-14928
5330-01-230-7032
Gasket
83-14929
4730-01-230-7060
Sediment Strainer Element
83-14940
5360-01-232-7733
Compression Helical Spring