1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-01-058-1265

5925-01-058-1265

Find complete technical information, availability, and procurement data for: 5925-01-058-1265

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-058-1265 to receive an up to date pricing and availability quote by email.

5925-01-058-1265
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-058-1265
Item Name Code
00136
Assigment Date
03/23/1978 (48 years ago)

An electrical fitting with electrical contacts, constructed to be affixed to the end of a cable, conduit, coaxial line, cord or wiring for convenience in joining with other electrical connector(s) or printed wiring board and is not designed to be mounted on a bulkhead, chasses, panel, printed wiring board, or the like. Excludes:jack, telephone; jack, tip; plug, telephone; plug tip; insert, electrical connector; connector body (as modified); and socket, plug-in, electronic components. See also lead assembly, electrical; wiring harness (as modified); and cable assembly (as modified). For items without inserts, see shell, electrical connector.

1.200 inches maximum body width, 1.530 inches nominal center to center distance between terminals parallel to length, 0.167 inches minimum and 0.177 inches maximum unthreaded mounting hole diameter, 3.250 inches maximum overall length, single pole type body style

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Overall Length
3.250 inches maximum
Body Width
1.200 inches maximum
Center To Center Distance Between Terminals Parallel To Length
1.530 inches nominal
Unthreaded Mounting Hole Diameter
0.167 inches minimum and 0.177 inches maximum
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.940 inches nominal
Switch Contact Arrangement
single pole, double throw
Fragility Factor
moderately rugged
Mounting Surface To Terminal End Distance
4.260 inches maximum
Pole Quantity
1
Mounting Facility Type And Quantity
2 unthreaded hole
Storage Type
general purpose warehouse
Maximum Continuous Load Current Rating Per Pole
50.0 amperes ac and 50.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
115.0 ac and 28.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3600.0 ac and 3600.0 dc single location
Circuit Protection Type
overcurrent single location
Trip Release Method
thermal single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
145.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Auxiliary Switch Function And Quantity
1 alarm
Internal Trip Release Configuration
series trip single location
Switch Location And Position Designation
internal at pole one
Trip Delay Time In Seconds Per Rated Continuous Current
13.000 minimum at 200 pct and 55.000 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
corrosion resistant and fungus resistant
Trip Release Ambient Temp Rating
25.0 celsius nominal single location
Switch Terminal Type
tab, solder lug
Switch Current Rating And Type In Amps
3.0 ac and 3.0 dc
Switch Voltage Rating And Type In Volts
115.0 ac and 28.0 dc
Unpackaged Unit Weight
0.750 pounds nominal
Frequency In Hertz
400.0 single location
Test Data Document
"81349--83383/02-09 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.)."
Terminal Type And Quantity
2 threaded stud
Specification/Standard Data
81349-mil-c-83383/2 government specification

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
6510-002-50 Circuit Breaker
M83383/02-09 Circuit Breaker
MIL-C-83383/2 Circuit Breaker
MIL-PRF-83383/2 Circuit Breaker
MIL-PRF-83383/2D Circuit Breaker
SM600BA50A1 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-058-1265?
The FSCG of the NSN 5925-01-058-1265 is 5925
Does the NSN 5925-01-058-1265 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-058-1265 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-058-1265 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-058-1265 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-058-1265 was assigned to the Federal Catalog?
It was assigned 48 years ago, on Thu, Mar 23, 1978

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

112-3807-030
3120-00-403-0444
Sleeve Bushing
112-382-1
2915-00-822-3500
Pump Discharge Case
112-383
2915-00-887-1915
Fuel Boost Pump Pumping Element
112-3830-0111-201
6210-00-655-0975
Indicator Light
112-3830-0112-201
6210-00-826-5747
Indicator Light
112-3830-0113-201
6210-00-660-8749
Indicator Light
112-3830-0116-201
6210-00-826-0622
Indicator Light
112-3830-112
6210-00-826-5747
Indicator Light
112-3830-116
6210-00-826-0622
Indicator Light
112-3837
4720-01-660-0786
Nonmetallic Hose Assembly
112-384
5950-01-016-3081
Special Transformer
112-387-3
5999-00-716-9426
Electrical-Electronic Heat Sink
112-387-5
5999-00-020-8328
Electrical-Electronic Heat Sink
112-39
6625-00-594-0323
Modulation Meter
112-3927
5306-01-714-7630
Machine Bolt