1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-01-057-2690

5925-01-057-2690

Find complete technical information, availability, and procurement data for: 5925-01-057-2690

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-057-2690 to receive an up to date pricing and availability quote by email.

5925-01-057-2690
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-057-2690
Item Name Code
00136
Assigment Date
03/09/1978 (48 years ago)

6.000 inches nominal body length, 4.469 inches nominal body width, multipole-single actuator type body style, 3.000 inches nominal body height, 5.250 inches nominal center to center distance between terminals parallel to length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
multipole-single actuator type
Body Length
6.000 inches nominal
Body Width
4.469 inches nominal
Body Height
3.000 inches nominal
Center To Center Distance Between Terminals Parallel To Length
5.250 inches nominal
Center To Center Distance Between Terminals Parallel To Width
1.500 inches nominal
Unthreaded Mounting Hole Diameter
0.172 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
5.125 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.500 inches nominal
Boss Height
0.125 inches nominal
Pole Quantity
3
Mounting Facility Type And Quantity
4 unthreaded hole
Storage Type
general purpose warehouse
Maximum Continuous Load Current Rating Per Pole
30.0 amperes ac and 30.0 amperes dc all locations
Operating Voltage Type And Rating Per Pole In Volts
480.0 ac and 250.0 dc all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
14000.0 ac and 14000.0 dc all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
thermal-magnetic all locations
Trip Release Characteristic
time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole two
Trip Delay Time In Seconds Per Rated Continuous Current
60.000 minimum at 200 pct and 200.000 maximum at 200 pct all locations
Inclosure Protection Type For Which Designed
fungus resistant
Trip Release Ambient Temp Rating
40.0 celsius nominal all locations
Frequency In Hertz
60.0 all locations
Material
plastic case
Terminal Type And Quantity
6 compression

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
FA-34030 Circuit Breaker
FA34030 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-057-2690?
The FSCG of the NSN 5925-01-057-2690 is 5925
Does the NSN 5925-01-057-2690 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-057-2690 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-057-2690 contain precious materials?
Precious metal content is unknown
Does NSN 5925-01-057-2690 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-057-2690 was assigned to the Federal Catalog?
It was assigned 48 years ago, on Thu, Mar 9, 1978

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

330D002G01
5998-00-061-2513
Circuit Card Assembly
330D004G01
5998-00-061-2514
Circuit Card Assembly
330D010G01
5998-00-061-2515
Circuit Card Assembly
330D016G01
5998-00-017-1409
Circuit Card Assembly
330D046
6110-00-202-2990
Voltage Regulator
330D106X9030C2
5910-00-098-9509
Electrolytic Fixed Capacitor
330D114
3020-01-100-9370
Internal Gear
330D138
3040-01-088-1614
Bevel Gearshaft
330D1A105G
5910-01-338-6821
Capacitor,fixed,metallized,paper
330D1C154K
5910-00-339-8962
Plastic Dielectr Fixed Capacitor
330D243G01
5998-00-942-2787
Circuit Card Assembly
330D445G01
5985-00-939-2481
Antenna
330D446
6625-00-927-4452
Teletypewriter Test Set
330D571
5905-00-284-3013
Wire Wound Fixed Resistor
330D712
5950-00-247-8897
Radio Frequency Transformer