DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-055-0170 to receive an up to date pricing and availability quote by email.

5925-01-055-0170
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-055-0170
Item Name Code
00136
Assigment Date
01/30/1978 (48 years ago)

A circular shaped item with an aperture manufactured to predetermined dimensions and designed for use as a seal in stuffing boxes, packing nuts, and the like. It may be (1) any nonmetallic molded or formed ring (except solid (without joint) rings having a square or rectangular cross section); or (2) any shredded metal or metal foil type metallic or semimetallic rings. Excludes:felt items but includes multimaterial items in which one of the materials is felt. For solid (without joints) nonmetallic items with a square or rectangular cross section, see washer (as modified) and gasket. For rubber items specifically designed for weather-proofing doors, windows, chests, and the like see seal, nonmetallic angle; seal, nonmetallic channel; and seal, nonmetallic, special shaped section. For circular (with aperature) nonmetallic items with a solid round cross-section see o-ring. Excludes:cup, compression; gasket; washer (as modified); and felt, mechanical, preformed.

multipole-multiple actuator type body style, 2.410 inches minimum and 2.510 inches maximum body length, 2.220 inches minimum and 2.280 inches maximum body width, 0.740 inches minimum and 0.760 inches maximum center to center distance between terminals parallel to width, 1.928 inches minimum and 1.948 inches maximum center to center distance between terminals parallel to length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
multipole-multiple actuator type
Body Length
2.410 inches minimum and 2.510 inches maximum
Body Width
2.220 inches minimum and 2.280 inches maximum
Center To Center Distance Between Terminals Parallel To Length
1.928 inches minimum and 1.948 inches maximum
Center To Center Distance Between Terminals Parallel To Width
0.740 inches minimum and 0.760 inches maximum
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.052 inches minimum and 2.072 inches maximum
Switch Contact Arrangement
single pole, double throw
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.740 inches minimum and 0.760 inches maximum
Fragility Factor
moderately rugged
Boss Height
0.130 inches minimum and 0.150 inches maximum
Mounting Surface To Terminal End Distance
2.330 inches minimum and 2.412 inches maximum
Pole Quantity
2
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
6 threaded hole
Storage Type
general purpose warehouse
Special Handling Feature
magnetic
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
1.0 amperes ac first location
Operating Voltage Type And Rating Per Pole In Volts
160.0 ac first location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
magnetic all locations
Trip Release Characteristic
time delay first location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
3 toggle
Actuator Function
trip-reset
Actuator Position Designation
at each pole
External Actuator Linkage Arrangement
one, two, and three linked
Auxiliary Switch Function And Quantity
1 alarm
Internal Trip Release Configuration
series trip first location
Nominal Thread Size
0.138 inches
Switch Location And Position Designation
internal at pole one
Trip Delay Time In Seconds Per Rated Continuous Current
0.150 minimum at 200 pct and 1.500 maximum at 200 pct first location
Inclosure Protection Type For Which Designed
corrosion resistant and moisture resistant and shockproof and vibrationproof and fungus resistant
Switch Terminal Type
pin
Switch Current Rating And Type In Amps
10.0 ac and 3.0 dc
Switch Voltage Rating And Type In Volts
250.0 ac and 50.0 dc
Unpackaged Unit Weight
0.438 pounds nominal
Special Features
pole two is switch only
Frequency In Hertz
60.0 all locations
Material
plastic case
Test Data Document
80063-sm-a-916395 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
Thread Series Designator
unc
Terminal Type And Quantity
6 threaded stud

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
AM2-Z94-1 Circuit Breaker
APL01-1REC2-5108-1 Circuit Breaker
SM-A-916395-1 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-055-0170?
The FSCG of the NSN 5925-01-055-0170 is 5925
Does the NSN 5925-01-055-0170 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-055-0170 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-055-0170 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-055-0170 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-055-0170 was assigned to the Federal Catalog?
It was assigned 48 years ago, on Mon, Jan 30, 1978

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

06.03 OPTION FT60096-02/7
4720-01-502-4122
Nonmetallic Hose
06.03 OPTION FT60096-02 REF.7
4720-01-502-4122
Nonmetallic Hose
06-030-000-32
5950-01-228-8220
Power Transformer
06-0300
6910-01-541-0427
Resuscitation Training Manikin
06-0301
6545-01-539-2732
Individual First Aid Kit
06-0301-0836-4
4130-01-081-7434
Air Conditioning Filter Element
06-0301-50
4920-01-585-8597
Test Set Accessory Kit
06-0301-54
5999-01-570-9346
Electronic Shielding Gasket
06-0302-0108
4130-01-023-6135
Air Conditioning Filter Element
06-0302-0111
4130-01-021-6946
Air Conditioning Filter Element
06-0302-0113
1680-01-441-8128
Aircraft Instruments Filter
06-0302-0114
4935-01-060-1458
Ventilating Panel
06-0302-0118
5999-01-665-7007
Electronic Components Shield
06-0302-0120
6610-01-178-5435
Cell Unit Shield
06-0302-0123
5999-01-304-9945
Radio Frequency-Electromag Panel