DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-053-5054 to receive an up to date pricing and availability quote by email.

5925-01-053-5054
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-053-5054
Item Name Code
00136
Assigment Date
01/05/1978 (48 years ago)

1.500 inches maximum body length, 0.844 inches minimum and 0.906 inches maximum center to center distance between terminals parallel to length, 0.625 inches maximum body width, 0.380 inches maximum bushing length, single pole type body style

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Bushing Length
0.380 inches maximum
Body Length
1.500 inches maximum
Body Width
0.625 inches maximum
Center To Center Distance Between Terminals Parallel To Length
0.844 inches minimum and 0.906 inches maximum
Switch Contact Arrangement
single pole, double throw
Fragility Factor
moderately rugged
Mounting Surface To Terminal End Distance
1.605 inches maximum
Pole Quantity
1
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
Storage Type
general purpose warehouse
Special Handling Feature
magnetic
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac single location
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic single location
Trip Release Characteristic
instantaneous single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Auxiliary Switch Function And Quantity
1 alarm
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.375 inches
Switch Location And Position Designation
internal at pole one
Inclosure Protection Type For Which Designed
hermetically sealed and shock resistant and vibration resistant
Switch Terminal Type
eyelet
Switch Current Rating And Type In Amps
0.5 ac and 0.5 dc
Switch Voltage Rating And Type In Volts
120.0 ac and 50.0 dc
Unpackaged Unit Weight
2.100 ounces nominal
Frequency In Hertz
400.0 single location
Thread Series Designator
unef
Terminal Type And Quantity
2 wire hook

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
99073765 Circuit Breaker
AP-1-1R-40-203 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-053-5054?
The FSCG of the NSN 5925-01-053-5054 is 5925
Does the NSN 5925-01-053-5054 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-053-5054 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-053-5054 contain precious materials?
Precious metal content is unknown
Does NSN 5925-01-053-5054 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-053-5054 was assigned to the Federal Catalog?
It was assigned 48 years ago, on Thu, Jan 5, 1978

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

3024-08
4820-01-226-3690
Foot Valve
3024-080
5970-01-189-6933
Electrical Insulation Sleeving
3024-1
3040-01-029-7393
Rigid Connecting Link
3024-10
6640-00-419-7000
Laboratory Graduated Cylinder
3024-10-340812
5935-01-300-9045
Electrical Connector Backshell
3024-10-441014
5935-01-301-2527
Electrical Connector Backshell
3024-10-441014-CS2359
5935-01-301-2527
Electrical Connector Backshell
3024-10-441116
5935-01-437-2530
Electrical Connector Backshell
3024-10-441316
5935-01-506-1030
Electrical Connector Backshell
3024-100
5970-01-078-4034
Electrical Insulation Sleeving
3024-1000
6640-00-420-3000
Laboratory Graduated Cylinder
3024-11
4820-01-226-1539
Check Valve
3024-11-340812
5935-01-437-2533
Electrical Connector Backshell
3024-120
5970-01-129-3557
Electrical Insulation Sleeving
3024-1203
5935-01-266-6118
Electrical Connector Backshell