Find complete technical information, availability, and procurement data for: 5925-01-048-7481

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-048-7481 to receive an up to date pricing and availability quote by email.

5925-01-048-7481
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-048-7481
Item Name Code
00136
Assigment Date
10/03/1977 (48 years ago)

1.555 inches minimum and 1.565 inches maximum center to center distance between terminals parallel to length, 0.745 inches minimum and 0.755 inches maximum body width, 1.665 inches minimum and 1.665 inches maximum distance between centerlines of mounting facilities parallel to body length, single pole type body style, 1.985 inches minimum and 2.015 inches maximum body length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Body Length
1.985 inches minimum and 2.015 inches maximum
Body Width
0.745 inches minimum and 0.755 inches maximum
Center To Center Distance Between Terminals Parallel To Length
1.555 inches minimum and 1.565 inches maximum
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.665 inches minimum and 1.665 inches maximum
Fragility Factor
moderately rugged
Boss Height
0.125 inches minimum and 0.135 inches maximum
Mounting Surface To Terminal End Distance
1.875 inches minimum and 1.885 inches maximum
Pole Quantity
1
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
2 threaded hole
Storage Type
general purpose warehouse
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
6.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic-hydraulic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
0.150 minimum at 200 pct and 1.500 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant and shockproof and vibrationproof
Unpackaged Unit Weight
2.500 ounces nominal
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
2 quick disconnect, male

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
111-300-032 Circuit Breaker
JA1-B3-6-3 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-048-7481?
The FSCG of the NSN 5925-01-048-7481 is 5925
Does the NSN 5925-01-048-7481 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-048-7481 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-048-7481 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-048-7481 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-048-7481 was assigned to the Federal Catalog?
It was assigned 48 years ago, on Mon, Oct 3, 1977

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

5LL2
6910-00-514-2033
Study Card Set
5LL2A41
5130-01-579-1728
Portable Pneumatic Drill
5LL30-00120
5915-01-530-7384
Low Pass Filter
5LL46
5120-01-504-9546
Screwdriver Bit Set and Handle
5LL50-30/XQ500-N/N
5915-01-503-4246
Low Pass Filter
5LL83
5120-01-694-7375
Hand Hammer
5LM1-D
5930-01-338-4778
Sensitive Switch
5LM1-E
5930-00-931-9370
Sensitive Switch
5LM10-2/2000/0
5895-01-431-7349
Multiplexer
5LM10-20X2000-0
5895-01-431-7349
Multiplexer
5LM50
5110-01-541-0985
Bent Trimmers Shears
5LNJ5
6150-00-642-1927
Electrical Lead
5LP1
5960-00-114-4665
Electron Tube
5LP1A
5960-00-170-4587
Electron Tube
5LP2-108A
4130-01-252-2358
Air Cooler Unit