5925-01-044-5508

Find complete technical information, availability, and procurement data for: 5925-01-044-5508

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-044-5508 to receive an up to date pricing and availability quote by email.

5925-01-044-5508
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-044-5508
Item Name Code
00136
Assigment Date
07/15/1977 (49 years ago)

2.046 inches minimum and 2.078 inches maximum distance between centerlines of mounting facilities parallel to body length, 2.510 inches maximum body length, single pole type body style, 1.660 inches minimum and 1.960 inches maximum center to center distance between terminals parallel to length, 0.730 inches minimum and 0.780 inches maximum body width

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Body Length
2.510 inches maximum
Body Width
0.730 inches minimum and 0.780 inches maximum
Center To Center Distance Between Terminals Parallel To Length
1.660 inches minimum and 1.960 inches maximum
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.046 inches minimum and 2.078 inches maximum
Fragility Factor
moderately rugged
Boss Height
0.109 inches minimum and 0.171 inches maximum
Mounting Surface To Terminal End Distance
2.553 inches maximum
Pole Quantity
1
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
2 threaded hole
Storage Type
general purpose warehouse
Special Handling Feature
magnetic
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
4.0 amperes ac single location
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
2.200 minimum at 200 pct and 20.000 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
moisture resistant and shock resistant and vibration resistant
Frequency In Hertz
60.0 single location
Material
plastic case
Test Data Document
"81349-mil-c-55629 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.)."
Thread Series Designator
unc
Terminal Type And Quantity
2 threaded stud
Specification/Standard Data
81349-mil-c-55629/1 government specification

Replaces National Stock Numbers

Below is a list of NSNs that have been officially superseded by this NSN:

NSN Name Date
5925-00-683-1640 No Name Available 08/01/1984
5925-00-852-2824 No Name Available 06/01/1992

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
8899720 Circuit Breaker
AM12MG3-4AMP117VACCURVE4 Circuit Breaker
M55629/1-038 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-044-5508?
The FSCG of the NSN 5925-01-044-5508 is 5925
Does the NSN 5925-01-044-5508 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-044-5508 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-044-5508 contain precious materials?
Precious metal content is unknown
Does NSN 5925-01-044-5508 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-044-5508 was assigned to the Federal Catalog?
It was assigned 49 years ago, on Fri, Jul 15, 1977

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

12388850
5340-01-462-6652
Mounting Plate
12388851
5340-01-462-6652
Mounting Plate
12388852
5340-01-462-1406
Access Cover
12388858
5340-01-462-6653
Mounting Bracket
12388859
6150-01-451-2024
E Special Purpose Cable Assembly
1238886-1
6105-00-578-7050
Motor-Tachometer Generato Stator
12388860
6120-01-458-1559
Power Supply
12388860-2
6120-01-469-0181
Power Supply
12388865
5998-01-456-9846
Circuit Card Assembly
12388870
6110-01-451-2013
Remote Switching Control
12388875
5998-01-465-7601
Electronic Components Assembly
12388877
6110-01-690-9987
Voltage Regulator Subassembly
12388879
6150-01-451-2019
Branched Wiring Harness
12388881-2
5998-01-465-7601
Electronic Components Assembly
12388887
6150-01-456-9839
Conductor Bus