5925-01-044-3890

Find complete technical information, availability, and procurement data for: 5925-01-044-3890

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-044-3890 to receive an up to date pricing and availability quote by email.

5925-01-044-3890
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-044-3890
Item Name Code
00136
Assigment Date
07/12/1977 (49 years ago)

1.660 inches minimum and 1.960 inches maximum center to center distance between terminals parallel to length, 2.510 inches maximum body length, +0.1177 to 0.1214 inches thread pitch diameters, single pole type body style, 0.730 inches minimum and 0.780 inches maximum body width

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Thread Pitch Diameters
+0.1177 to 0.1214 inches
Body Style
single pole type
Body Length
2.510 inches maximum
Body Width
0.730 inches minimum and 0.780 inches maximum
Center To Center Distance Between Terminals Parallel To Length
1.660 inches minimum and 1.960 inches maximum
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.046 inches minimum and 2.078 inches maximum
Switch Contact Arrangement
single pole, double throw
Fragility Factor
moderately rugged
Boss Height
0.140 inches nominal
Mounting Surface To Terminal End Distance
2.800 inches maximum
Pole Quantity
1
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
2 threaded hole
Storage Type
general purpose warehouse
Special Handling Feature
magnetic
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
25.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 dc single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Auxiliary Switch Function And Quantity
1 alarm
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.138 inches
Switch Location And Position Designation
internal at pole one
Trip Delay Time In Seconds Per Rated Continuous Current
0.180 minimum at 200 pct and 2.000 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant and salt spray proof and shock resistant and vibration resistant
Switch Terminal Type
knife blade
Switch Current Rating And Type In Amps
10.0 ac and 2.0 dc
Switch Voltage Rating And Type In Volts
250.0 ac and 50.0 dc
Material
plastic case
Test Data Document
"81349-mil-c-55629 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.)."
Thread Series Designator
unc
Terminal Type And Quantity
2 threaded stud
Specification/Standard Data
81349-mil-c-55629/2 government specification

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
AM1-D3-A-25-3 Circuit Breaker
AM1-Z24-107 Circuit Breaker
APL-1-1R0-55629/2-107 Circuit Breaker
M55629/2-107 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-044-3890?
The FSCG of the NSN 5925-01-044-3890 is 5925
Does the NSN 5925-01-044-3890 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-044-3890 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-044-3890 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-044-3890 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-044-3890 was assigned to the Federal Catalog?
It was assigned 49 years ago, on Tue, Jul 12, 1977

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

9-2-9810
5410-01-720-9400
Prefabricated Building Panel
9-2-9810-1
5410-01-721-4844
Prefabricated Building Panel
9-2-9810-2
5410-01-720-9400
Prefabricated Building Panel
9-2-9811
5410-01-721-4565
Prefabricated Building Panel
9-2-9811-1
5410-01-721-4853
Prefabricated Building Panel
9-2-9811-2
5410-01-721-4565
Prefabricated Building Panel
9-2-9812
5410-01-720-9394
Prefabricated Building Panel
9-2-9812-1
5410-01-720-9881
Prefabricated Building Panel
9-2-9812-2
5410-01-720-9394
Prefabricated Building Panel
9-2-9813
5410-01-721-2339
Prefabricated Building Panel
9-2-9813-1
5410-01-721-4836
Prefabricated Building Panel
9-2-9813-2
5410-01-721-2339
Prefabricated Building Panel
9-2-9814
5410-01-727-5843
Prefabricated Building Panel
9-2-9814-1
5410-01-727-5843
Prefabricated Building Panel
9-2-9814-2
5410-01-727-6102
Prefabricated Building Panel