Find complete technical information, availability, and procurement data for: 5925-01-044-0309

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-044-0309 to receive an up to date pricing and availability quote by email.

5925-01-044-0309
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-044-0309
Item Name Code
00136
Assigment Date
07/05/1977 (49 years ago)

A resistor whose ohmic value cannot be adjusted or varied. The resistance element consists of either a thin layer of conductive material, containing either binders or insulating materials, deposited on an insulated form; or an alloy of metal and ceramic materials, usually fused to an insulated form. Opposition to the flow of current is an inherent property of the materials used and is manifest by the heat dissipation in the resistor. See also attenuator, fixed and resistor, fixed, composition. Excludes:carbon composition type resistors.

1.562 inches maximum body length, 0.332 inches minimum and 0.380 inches maximum bushing length, 1.937 inches maximum body width, +0.3503 to 0.3537 inches thread pitch diameters, multipole-single actuator type body style

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Thread Pitch Diameters
+0.3503 to 0.3537 inches
Body Style
multipole-single actuator type
Bushing Length
0.332 inches minimum and 0.380 inches maximum
Body Length
1.562 inches maximum
Body Width
1.937 inches maximum
Center To Center Distance Between Terminals Parallel To Length
0.906 inches maximum
Center To Center Distance Between Terminals Parallel To Width
0.594 inches minimum and 0.656 inches maximum
Nonturn Device Radius
0.610 inches minimum and 0.640 inches maximum
Nonturn Device Diameter
0.235 inches minimum and 0.265 inches maximum
Fragility Factor
moderately rugged
Mounting Surface To Terminal End Distance
1.828 inches maximum
Pole Quantity
3
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
Storage Type
general purpose warehouse
Special Handling Feature
magnetic
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac and 10.0 amperes dc all locations
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac and 50.0 dc all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac and 1000.0 dc all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
magnetic all locations
Trip Release Characteristic
time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole two
Internal Trip Release Configuration
series trip all locations
Nominal Thread Size
0.375 inches
Trip Delay Time In Seconds Per Rated Continuous Current
0.500 minimum at 200 pct and 9.000 maximum at 200 pct all locations
Inclosure Protection Type For Which Designed
fungus resistant and vibrationproof and moisture resistant and shockproof and salt spray proof and hermetically sealed
Unpackaged Unit Weight
5.400 ounces nominal
Frequency In Hertz
60.0 or 400.0 all locations
Test Data Document
"81349-mil-c-39019 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.)."
Thread Series Designator
unef
Terminal Type And Quantity
6 wire hook
Specification/Standard Data
81349-mil-c-39019/5 government specification

Replaces National Stock Numbers

Below is a list of NSNs that have been officially superseded by this NSN:

NSN Name Date
5925-00-787-8780 No Name Available 05/01/1995
5925-00-811-8044 No Name Available 11/01/1992
5925-01-065-8351 No Name Available 05/01/1995

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
38553 FIND 9 Circuit Breaker
51303-022 Circuit Breaker
7907117-11 Circuit Breaker
AP-112-1-41-103 Circuit Breaker
AP-MIL-1-7-2-103 Circuit Breaker
M39019/05-249 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-044-0309?
The FSCG of the NSN 5925-01-044-0309 is 5925
Does the NSN 5925-01-044-0309 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-044-0309 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-044-0309 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-044-0309 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-044-0309 was assigned to the Federal Catalog?
It was assigned 49 years ago, on Tue, Jul 5, 1977

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

A9313
1680-00-571-2180
Actuator B Retainer
A9313-1
5310-01-248-1272
Flat Washer
A9314
2920-00-495-3301
Ignition Distributor Weight
A9314-1
5340-01-133-4628
Bow Handle
A9315
1680-00-948-4311
Actuator Gear
A9316
1680-00-570-7558
Actuator Parts Kit
A9316-6152-002
5961-00-985-9074
Transistor
A93166S
4130-01-189-5590
Deck Diagonal Stop
A9317
5310-00-424-3258
Flat Washer
A9317BL
4930-00-737-4114
Thro Lever Assembly
A9317BR
4930-00-737-0076
Thro Lever Assembly
A9318
5305-00-353-7510
Assembled Washer Screw
A931A8S20
5325-00-171-4688
Nonmetallic Grommet
A932
5910-00-112-7408
Paper Dielectric Fixed Capacitor
A9320
4320-01-200-8712
Dirt and Liquid Deflector