Find complete technical information, availability, and procurement data for: 5925-01-040-6214

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-040-6214 to receive an up to date pricing and availability quote by email.

5925-01-040-6214
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-040-6214
Item Name Code
00136
Assigment Date
05/11/1977 (49 years ago)

An electrical fitting with electrical contacts, constructed to be affixed to the end of a cable, conduit, coaxial line, cord or wiring for convenience in joining with other electrical connector(s) or printed wiring board and is not designed to be mounted on a bulkhead, chasses, panel, printed wiring board, or the like. Excludes:jack, telephone; jack, tip; plug, telephone; plug tip; insert, electrical connector; connector body (as modified); and socket, plug-in, electronic components. See also lead assembly, electrical; wiring harness (as modified); and cable assembly (as modified). For items without inserts, see shell, electrical connector.

2.000 inches nominal body length, 1.515 inches minimum and 1.545 inches maximum center to center distance between terminals parallel to length, 2.265 inches maximum body width, multipole-single actuator type body style, +0.4752 to 0.4787 inches thread pitch diameters

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Thread Pitch Diameters
+0.4752 to 0.4787 inches
Body Style
multipole-single actuator type
Body Length
2.000 inches nominal
Body Width
2.265 inches maximum
Center To Center Distance Between Terminals Parallel To Length
1.515 inches minimum and 1.545 inches maximum
Center To Center Distance Between Terminals Parallel To Width
0.735 inches minimum and 0.765 inches maximum
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.660 inches nominal
Nonturn Device Radius
0.656 inches nominal
Nonturn Device Length
0.130 inches nominal
Nonturn Device Diameter
0.151 inches minimum and 0.161 inches maximum
Switch Contact Arrangement
single pole, double throw
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.735 inches minimum and 0.765 inches maximum
Fragility Factor
moderately rugged
Boss Height
0.130 inches nominal
Mounting Surface To Terminal End Distance
2.032 inches maximum
Pole Quantity
3
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
Storage Type
general purpose warehouse
Special Handling Feature
magnetic
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
6.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
115.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
magnetic-hydraulic all locations
Trip Release Characteristic
time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole two
Auxiliary Switch Function And Quantity
1 alarm
Internal Trip Release Configuration
series trip all locations
Nominal Thread Size
0.500 inches
Switch Location And Position Designation
internal at pole three
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 minimum at 200 pct and 20.000 maximum at 200 pct all locations
Inclosure Protection Type For Which Designed
corrosion resistant and moisture resistant and shockproof and vibrationproof
Switch Terminal Type
pin
Switch Current Rating And Type In Amps
10.0 ac and 3.0 dc
Switch Voltage Rating And Type In Volts
250.0 ac and 50.0 dc
Unpackaged Unit Weight
9.000 ounces nominal
Frequency In Hertz
60.0 all locations
Material
plastic case
Thread Series Designator
un
Terminal Type And Quantity
6 screw

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
856591-4 Circuit Breaker
APGN-666-1REC2-2879-4 Circuit Breaker
APGN-666-2879-4 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-040-6214?
The FSCG of the NSN 5925-01-040-6214 is 5925
Does the NSN 5925-01-040-6214 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-040-6214 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-040-6214 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-040-6214 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-040-6214 was assigned to the Federal Catalog?
It was assigned 49 years ago, on Wed, May 11, 1977

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

SY-9505
1620-01-159-8292
Shock Bleed
SY/97-25-107
5310-01-363-0739
Flat Washer
SY/97-37-518
4730-01-629-1271
Packing Nut
SY-ACC65047
5180-01-647-4905
Communication Mechanic' Tool Kit
SY-ADA24040
7025-01-682-6880
Dongle
SY-ADA24052
7025-01-682-6880
Dongle
SY-ADA31025
6150-01-673-7274
E Special Purpose Cable Assembly
SY-B-150F
4730-01-293-2959
Sediment Strainer Element
SY-B-150F-1.5
4730-01-293-2957
Sediment Strainer
SY-B-150F-1.5-2
4730-01-293-2959
Sediment Strainer Element
SY-B-150F-1.5-4
5330-01-292-5305
Gasket
SY-B-150F 1IN 1
4730-01-306-6410
Sediment Strainer
SY-B-150F 1IN 100MESH FLG BRZ
4730-01-307-0162
Sediment Strainer
SY-B-150F-1IN 100MESH SS FLG BRZ
4730-01-306-6410
Sediment Strainer
SY-B-150F 2 1/2IN BRZ .045
4730-01-305-5853
Sediment Strainer