1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-01-037-1490

5925-01-037-1490

Find complete technical information, availability, and procurement data for: 5925-01-037-1490

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-037-1490 to receive an up to date pricing and availability quote by email.

5925-01-037-1490
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-037-1490
Item Name Code
00136
Assigment Date
03/14/1977 (49 years ago)

2.062 inches nominal distance between centerlines of mounting facilities parallel to body length, 0.750 inches nominal body width, single pole type body style, 2.500 inches nominal body length, 1.938 inches nominal center to center distance between terminals parallel to length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Body Length
2.500 inches nominal
Body Width
0.750 inches nominal
Center To Center Distance Between Terminals Parallel To Length
1.938 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.062 inches nominal
Switch Contact Arrangement
single pole, double throw
Fragility Factor
moderately rugged
Mounting Surface To Terminal End Distance
2.409 inches minimum and 2.533 inches maximum
Pole Quantity
1
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
2 threaded hole
Storage Type
general purpose warehouse
Special Handling Feature
magnetic
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
2.5 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
65.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 dc single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic-hydraulic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Auxiliary Switch Function And Quantity
1 alarm
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.138 inches
Switch Location And Position Designation
internal at pole one
Trip Delay Time In Seconds Per Rated Continuous Current
0.150 minimum at 200 pct and 1.500 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
Switch Terminal Type
tab, solder lug
Switch Current Rating And Type In Amps
10.0 ac and 4.0 dc
Switch Voltage Rating And Type In Volts
250.0 ac and 30.0 dc
Unpackaged Unit Weight
0.188 pounds nominal
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
2 threaded stud

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
204-18572-16 Circuit Breaker
AM1-Z142-5 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-037-1490?
The FSCG of the NSN 5925-01-037-1490 is 5925
Does the NSN 5925-01-037-1490 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-037-1490 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-037-1490 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-01-037-1490 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-037-1490 was assigned to the Federal Catalog?
It was assigned 49 years ago, on Mon, Mar 14, 1977

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

HL57-10-14
5320-01-532-4198
Pin-Rivet
HL57-10-15
5320-00-395-6459
Pin-Rivet
HL57-10-20
5320-00-395-6458
Pin-Rivet
HL57-6-10
5320-00-929-9233
Pin-Rivet
HL57-6-12
5320-00-929-9231
Pin-Rivet
HL57-6-13
5320-01-281-1873
Pin-Rivet
HL57-6-2
5320-00-929-9229
Pin-Rivet
HL57-6-3
5320-00-959-7200
Pin-Rivet
HL57-6-4
5320-00-959-0252
Pin-Rivet
HL57-6-5
5320-00-959-0249
Pin-Rivet
HL57-6-6
5320-00-929-9228
Pin-Rivet
HL57-6-7
5320-00-959-0248
Pin-Rivet
HL57-6-8
5320-00-959-0244
Pin-Rivet
HL57-6-9
5320-00-959-0243
Pin-Rivet
HL57-8-10
5320-00-929-6592
Pin-Rivet