1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-01-028-3612

5925-01-028-3612

Find complete technical information, availability, and procurement data for: 5925-01-028-3612

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-01-028-3612 to receive an up to date pricing and availability quote by email.

5925-01-028-3612
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-01-028-3612
Item Name Code
00136
Assigment Date
09/30/1976 (49 years ago)

1.875 inches maximum body width, +0.3503 to 0.3537 inches thread pitch diameters, 1.500 inches maximum body length, multipole-single actuator type body style, 0.380 inches maximum bushing length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Thread Pitch Diameters
+0.3503 to 0.3537 inches
Body Style
multipole-single actuator type
Bushing Length
0.380 inches maximum
Body Length
1.500 inches maximum
Body Width
1.875 inches maximum
Center To Center Distance Between Terminals Parallel To Length
0.844 inches minimum and 0.906 inches maximum
Center To Center Distance Between Terminals Parallel To Width
0.594 inches minimum and 0.656 inches maximum
Fragility Factor
moderately rugged
Mounting Surface To Terminal End Distance
1.780 inches maximum
Pole Quantity
3
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
Storage Type
general purpose warehouse
Special Handling Feature
magnetic
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
1.25 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
magnetic all locations
Trip Release Characteristic
time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole two
Internal Trip Release Configuration
series trip all locations
Nominal Thread Size
0.375 inches
Trip Delay Time In Seconds Per Rated Continuous Current
0.900 minimum at 200 pct and 4.000 maximum at 200 pct all locations
Inclosure Protection Type For Which Designed
hermetically sealed and shock resistant and vibration resistant
Frequency In Hertz
400.0 all locations
Thread Series Designator
unef
Terminal Type And Quantity
6 wire hook

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
841003-2 Circuit Breaker
AP112-2408-2 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-01-028-3612?
The FSCG of the NSN 5925-01-028-3612 is 5925
Does the NSN 5925-01-028-3612 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-01-028-3612 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-01-028-3612 contain precious materials?
Precious metal content is unknown
Does NSN 5925-01-028-3612 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-01-028-3612 was assigned to the Federal Catalog?
It was assigned 49 years ago, on Thu, Sep 30, 1976

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

469-6404524-AY98
1290-01-425-1413
Electrical-Electro Control Panel
469-6404524-AY99
1290-01-433-3911
Electrical-Electro Control Panel
469-6404525-43
5930-01-426-8748
Rotary Switch
469-6404525-46
5980-01-430-4579
Optoelectronic Control-Display
469-6404525-60
5305-01-428-4069
Thumbscrew
469-6404525-90
5998-01-424-4325
Electronic Components Assembly
469-6404525-AY96
1290-01-425-4280
Electrical-Electro Control Panel
469-6404525-AY97
1290-01-425-4224
Electrical-Electro Control Panel
469-6404525-AY98
1290-01-534-9077
Electrical-Electro Control Panel
469-6404525-AY99
1290-01-425-1500
Electrical-Electro Control Panel
469-6404526-14
5340-01-457-7511
Bow Handle
469-6404526-2
5930-01-431-0527
Rotary Switch
469-6404526-AY99
1290-01-428-9278
Electrical-Electro Control Panel
469-6404527
5895-01-483-4418
Lens Cap
469-6404527-15
5930-01-426-8730
Push Switch