DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-995-0193 to receive an up to date pricing and availability quote by email.
A relay switch which is actuated by the effect of internal heat generated by the current in its energizing circuit. For items actuated by ambient, rather than internal temperature changes, see switch, thermostatic.
0.750 inches nominal center to center distance between terminals parallel to width, 2.250 inches nominal body width, 2.500 inches nominal body length, multipole-multiple actuator type body style, 1.938 inches nominal center to center distance between terminals parallel to length
Product Characteristics
Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.
- Body Style
- multipole-multiple actuator type
- Body Length
- 2.500 inches nominal
- Body Width
- 2.250 inches nominal
- Center To Center Distance Between Terminals Parallel To Length
- 1.938 inches nominal
- Center To Center Distance Between Terminals Parallel To Width
- 0.750 inches nominal
- Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
- 2.062 inches nominal
- Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
- 0.750 inches nominal
- Fragility Factor
- moderately rugged
- Boss Height
- 0.140 inches nominal
- Mounting Surface To Terminal End Distance
- 2.611 inches nominal
- Pole Quantity
- 3
- Arc Quenching Method
- air
- Mounting Facility Type And Quantity
- 6 threaded hole
- Storage Type
- general purpose warehouse
- Thread Quantity Per Inch
- 32
- Maximum Continuous Load Current Rating Per Pole
- 1.0 amperes dc first location
- Maximum Continuous Load Current Rating Per Pole
- 2.0 amperes ac second location
- Maximum Continuous Load Current Rating Per Pole
- 2.0 amperes ac third location
- Operating Voltage Type And Rating Per Pole In Volts
- 250.0 ac second location
- Operating Voltage Type And Rating Per Pole In Volts
- 250.0 ac third location
- Operating Voltage Type And Rating Per Pole In Volts
- 50.0 dc first location
- Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
- 2000.0 dc first location
- Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
- 1000.0 ac second location
- Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
- 1000.0 ac third location
- Circuit Protection Type
- overcurrent all locations
- Trip Release Method
- magnetic-hydraulic all locations
- Trip Release Characteristic
- time delay all locations
- Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
- 150.0 all locations
- Reset Method
- manual
- Main Contact Tripping Mechanism Type
- trip free
- Manual Actuator Type And Quantity
- 3 toggle
- Actuator Function
- trip-reset
- Actuator Position Designation
- at each pole
- External Actuator Linkage Arrangement
- one, two, and three linked
- Internal Trip Release Configuration
- series trip all locations
- Nominal Thread Size
- 0.138 inches
- Trip Delay Time In Seconds Per Rated Continuous Current
- 12.500 nominal at 200 pct second location
- Trip Delay Time In Seconds Per Rated Continuous Current
- 12.500 nominal at 200 pct third location
- Trip Delay Time In Seconds Per Rated Continuous Current
- 5.000 nominal at 200 pct first location
- Inclosure Protection Type For Which Designed
- fungus resistant and moisture resistant
- Frequency In Hertz
- 60.0 third location
- Frequency In Hertz
- 60.0 second location
- Material
- plastic case
- Test Data Document
- 01714-g383753 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
- Thread Series Designator
- unc
- Terminal Type And Quantity
- 6 threaded stud
Related Parts
This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:
| Part Number | Name |
|---|---|
| 72-218-1MG6 | Circuit Breaker |
| AM333MG6-1-2-2-50VDC250VAC60C2 | Circuit Breaker |
| G383753 | Circuit Breaker |
FAQs
Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.
What is the FSCG of the NSN 5925-00-995-0193?
Does the NSN 5925-00-995-0193 have a Schedule B code assigned?
Does NSN 5925-00-995-0193 require demilitarization?
Does NSN 5925-00-995-0193 contain precious materials?
Does NSN 5925-00-995-0193 contain hazardous materials?
When the NSN 5925-00-995-0193 was assigned to the Federal Catalog?
Professional Distribution
Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.
- ITAR Registered
- DDTC Registered
- HAZMAT Certified
- AS9120 Quality Standards
- 100% Quality Inspections
You May Also Like
Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.
Pricing
Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information: