Find complete technical information, availability, and procurement data for: 5925-00-984-4556

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-984-4556 to receive an up to date pricing and availability quote by email.

5925-00-984-4556
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-984-4556
Item Name Code
00136
Assigment Date
01/01/1962 (64 years ago)

1.190 inches nominal center to center distance between terminals parallel to length, 0.750 inches nominal body width, 1.812 inches nominal distance between centerlines of mounting facilities parallel to body length, 2.500 inches nominal body length, single pole type body style

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Body Length
2.500 inches nominal
Body Width
0.750 inches nominal
Center To Center Distance Between Terminals Parallel To Length
1.190 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.812 inches nominal
Fragility Factor
moderately rugged
Mounting Surface To Terminal End Distance
2.000 inches nominal
Pole Quantity
1
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
2 threaded hole
Storage Type
general purpose warehouse
Special Handling Feature
magnetic
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
200.0 milliamperes ac single location
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3500.0 ac single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic-hydraulic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
0.300 minimum at 200 pct and 1.000 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
explosion resistant
Frequency In Hertz
60.0 single location
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
2 screw

Replaces National Stock Numbers

Below is a list of NSNs that have been officially superseded by this NSN:

NSN Name Date
5925-00-055-9377 No Name Available 03/01/1967

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
AM17-0.2-120-60-56 Circuit Breaker
DMS90 031B Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-984-4556?
The FSCG of the NSN 5925-00-984-4556 is 5925
Does the NSN 5925-00-984-4556 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-984-4556 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-984-4556 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-00-984-4556 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-984-4556 was assigned to the Federal Catalog?
It was assigned 64 years ago, on Mon, Jan 1, 1962

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

30-504UUF600V
5910-00-621-9470
Plastic Dielectr Fixed Capacitor
30-505
5935-01-655-1530
Electrical Plug Connector
30-50505-03
5895-01-230-6386
Transmitter Subassembly
30-5052-00009
5330-01-273-3805
Preformed Packing
30-506
5120-01-525-4545
Crimpmaster
30-50663-01
6130-01-231-9245
Power Supply
30-50683-01
6130-01-232-9598
Power Supply
30-50703-01
6130-01-483-8267
Power Supply
30-508-00
3020-01-105-4072
Silent Chain
30-508-20
3020-01-105-4072
Silent Chain
30-508672
5330-00-087-2296
Plain Encased Seal
30-51
5330-01-246-2564
Gasket
30 51 32
6650-01-139-9519
Objective Microscope
30 51 46
6650-01-139-9521
Objective Microsc
30-510
5940-01-090-0465
Conductor Splice