5925-00-984-3004

Find complete technical information, availability, and procurement data for: 5925-00-984-3004

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-984-3004 to receive an up to date pricing and availability quote by email.

5925-00-984-3004
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-984-3004
Item Name Code
00136
Assigment Date
10/19/1966 (59 years ago)

1.375 inches nominal center to center distance between terminals parallel to width, multipole-single actuator type body style, 2.750 inches nominal body width, 3.375 inches nominal body height, 6.000 inches nominal body length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
multipole-single actuator type
Body Length
6.000 inches nominal
Body Width
2.750 inches nominal
Body Height
3.375 inches nominal
Center To Center Distance Between Terminals Parallel To Width
1.375 inches nominal
Unthreaded Mounting Hole Diameter
0.187 inches nominal
Fragility Factor
moderately rugged
Boss Height
0.125 inches nominal
Pole Quantity
2
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
2 unthreaded hole
Storage Type
general purpose warehouse
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac and 15.0 amperes dc all locations
Operating Voltage Type And Rating Per Pole In Volts
480.0 ac and 250.0 dc all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
15000.0 ac and 10000.0 dc all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
thermal-magnetic all locations
Trip Release Characteristic
time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Trip Delay Time In Seconds Per Rated Continuous Current
29.000 minimum at 200 pct and 110.000 maximum at 200 pct all locations
Inclosure Protection Type For Which Designed
hermetically sealed
Trip Release Ambient Temp Rating
50.0 celsius maximum all locations
Frequency In Hertz
60.0 all locations
Material
plastic case
Terminal Type And Quantity
4 screw

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
3200749-1 Circuit Breaker
EH2015V Circuit Breaker
EHB2015V Circuit Breaker
EHD2015V Circuit Breaker
END2015V Circuit Breaker
S451D855G01 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-984-3004?
The FSCG of the NSN 5925-00-984-3004 is 5925
Does the NSN 5925-00-984-3004 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-984-3004 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-984-3004 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-00-984-3004 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-984-3004 was assigned to the Federal Catalog?
It was assigned 59 years ago, on Wed, Oct 19, 1966

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

UPA94501-1
5995-01-686-4004
E Special Purpose Cable Assembly
UPA94504-1
5995-01-687-9954
E Special Purpose Cable Assembly
UPA94507-1
5995-01-573-0727
E Special Purpose Cable Assembly
UPA94507-2
5995-01-567-7339
E Special Purpose Cable Assembly
UPA94507-3
5995-01-685-6084
E Special Purpose Cable Assembly
UPA94509-1
5995-01-567-5151
E Special Purpose Cable Assembly
UPA94510-7
5995-01-591-2055
E Special Purpose Cable Assembly
UPA94515-1
5995-01-591-7773
E Special Purpose Cable Assembly
UPA94523-1
5995-01-701-0027
E Special Purpose Cable Assembly
UPA94528-1
5995-01-673-6480
E Special Purpose Cable Assembly
UPA94555-4
5995-01-648-8252
Radio Frequency Cable Assembly
UPA95001-6
5995-01-513-0629
E Special Purpose Cable Assembly
UPA95002-1
5995-01-513-0634
E Special Purpose Cable Assembly
UPA95002-2
5995-01-628-8638
E Special Purpose Cable Assembly
UPA95002-3
5995-01-511-8500
E Special Purpose Cable Assembly