1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-00-979-9134

5925-00-979-9134

Find complete technical information, availability, and procurement data for: 5925-00-979-9134

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-979-9134 to receive an up to date pricing and availability quote by email.

5925-00-979-9134
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-979-9134
Item Name Code
00136
Assigment Date
01/01/1962 (64 years ago)

0.844 inches minimum and 0.906 inches maximum center to center distance between terminals parallel to length, 1.562 inches maximum body length, 1.281 inches maximum body width, multipole-single actuator type body style, 0.380 inches maximum bushing length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
multipole-single actuator type
Bushing Length
0.380 inches maximum
Body Length
1.562 inches maximum
Body Width
1.281 inches maximum
Center To Center Distance Between Terminals Parallel To Length
0.844 inches minimum and 0.906 inches maximum
Center To Center Distance Between Terminals Parallel To Width
0.594 inches minimum and 0.656 inches maximum
Fragility Factor
moderately rugged
Mounting Surface To Terminal End Distance
1.780 inches maximum
Pole Quantity
2
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
Storage Type
general purpose warehouse
Special Handling Feature
magnetic
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
3.6 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
230.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
magnetic all locations
Trip Release Characteristic
time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
between pole one and two
Internal Trip Release Configuration
series trip all locations
Nominal Thread Size
0.375 inches
Trip Delay Time In Seconds Per Rated Continuous Current
0.070 minimum at 200 pct and 0.700 maximum at 200 pct all locations
Inclosure Protection Type For Which Designed
hermetically sealed and shockproof and vibrationproof
Unpackaged Unit Weight
1.800 ounces nominal
Frequency In Hertz
60.0 all locations
Thread Series Designator
unef
Terminal Type And Quantity
4 wire hook

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
711520-55 Circuit Breaker
711520-55REVA Circuit Breaker
78-100-1 Circuit Breaker
78-100-1-3-6-230-60-1 Circuit Breaker
AP1-35-55 Circuit Breaker
AP12-35-55 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-979-9134?
The FSCG of the NSN 5925-00-979-9134 is 5925
Does the NSN 5925-00-979-9134 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-979-9134 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-979-9134 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-00-979-9134 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-979-9134 was assigned to the Federal Catalog?
It was assigned 64 years ago, on Mon, Jan 1, 1962

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

MILP18526
4320-00-443-5605
Rotary Pump Unit
MILP18547
4320-00-403-1297
Rotary Pump Unit
MILP18682
4320-00-115-5084
Centrifugal Pump Unit
MILP18707TYPE2
6130-00-557-0170
Power Supply
MILP1877TYGEE0-0
5970-00-912-4769
Electrical Insulation Sheet
MILP18871
5330-00-096-3242
Preformed Packing
MILP19119
4710-00-554-4659
Plastic Pipe
MILP19131
4320-00-242-6390
Rotary Pump Unit
MILP19131 4.5GP
4320-01-205-0525
Rotary Pump Unit
MILP19152
5330-00-223-2756
Preformed Packing
MILP19177TYGEB0-
5970-00-571-8270
Electrical Insulation Sheet
MILP19232
7530-00-515-1605
Facsimile Recording Paper
MILP19380
2040-00-690-9721
Stabilizer Towe Connection Angle
MILP19421
6130-00-088-4087
Power Supply
MILP19421ATYPE1
6130-00-556-8465
Power Supply