DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-957-6020 to receive an up to date pricing and availability quote by email.

5925-00-957-6020
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-957-6020
Item Name Code
00136
Assigment Date
01/01/1960 (66 years ago)

single pole type body style, 2.500 inches nominal body length, 1.812 inches nominal distance between centerlines of mounting facilities parallel to body length, 1.190 inches nominal center to center distance between terminals parallel to length, 0.750 inches nominal body width

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Body Length
2.500 inches nominal
Body Width
0.750 inches nominal
Center To Center Distance Between Terminals Parallel To Length
1.190 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.812 inches nominal
Fragility Factor
moderately rugged
Mounting Surface To Terminal End Distance
2.000 inches nominal
Pole Quantity
1
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
2 threaded hole
Storage Type
general purpose warehouse
Special Handling Feature
magnetic
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
1.0 amperes ac single location
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3500.0 ac single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic-hydraulic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
2.800 minimum at 200 pct and 8.500 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
explosion resistant
Unpackaged Unit Weight
4.250 ounces nominal
Frequency In Hertz
400.0 single location
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
2 screw

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
11-135-40-400 Circuit Breaker
AM17-1-120-55-400 Circuit Breaker
AM17-1-120VAC400CPS55 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-957-6020?
The FSCG of the NSN 5925-00-957-6020 is 5925
Does the NSN 5925-00-957-6020 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-957-6020 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-957-6020 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-00-957-6020 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-957-6020 was assigned to the Federal Catalog?
It was assigned 66 years ago, on Fri, Jan 1, 1960

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

KYW224
5340-01-334-2898
Spacing Threaded Standoff
KYW354-1
5935-01-325-3520
Electrical Receptacle Connector
KYX-15A
5810-01-095-1312
Kyx 15a Tsec
KYX-2021
2940-00-976-9010
Intake Air Cleane Filter Element
KYX00-0460
2940-00-858-8179
Intake Air Cleane Filter Element
KYX00-0461
2940-00-910-3066
Intake Air Cleane Filter Element
KYX00-2022
2940-00-074-3584
Intake Air Cleane Filter Element
KYX00-2486
2940-00-074-3584
Intake Air Cleane Filter Element
KYX00-4476
4730-01-276-5000
Tube Repair Clamp
KYX00-4478
4730-01-123-5019
Pipe Repair Clamp
KYX00-4480
5340-01-190-0403
Loop Clamp
KYX00-4482
5340-01-129-1755
Loop Clamp
KYX00-4484
5340-01-239-8956
Loop Clamp
KYX00-4537
4730-01-139-4226
Clamp Seal
KYX00-4538
5340-01-244-2463
Loop Clamp