1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-00-957-0468

5925-00-957-0468

Find complete technical information, availability, and procurement data for: 5925-00-957-0468

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-957-0468 to receive an up to date pricing and availability quote by email.

5925-00-957-0468
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-957-0468
Item Name Code
00136
Assigment Date
01/01/1962 (64 years ago)

multipole-multiple actuator type body style, 3.052 inches minimum and 3.072 inches maximum center to center distance between terminals parallel to length, 4.490 inches minimum and 4.510 inches maximum body width, 5.240 inches minimum and 5.260 inches maximum body length, 2.677 inches minimum and 2.697 inches maximum body height

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
multipole-multiple actuator type
Body Length
5.240 inches minimum and 5.260 inches maximum
Body Width
4.490 inches minimum and 4.510 inches maximum
Body Height
2.677 inches minimum and 2.697 inches maximum
Center To Center Distance Between Terminals Parallel To Length
3.052 inches minimum and 3.072 inches maximum
Center To Center Distance Between Terminals Parallel To Width
0.990 inches minimum and 1.010 inches maximum
Unthreaded Mounting Hole Diameter
0.190 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.349 inches minimum and 4.369 inches maximum
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.974 inches minimum and 0.994 inches maximum
Fragility Factor
moderately rugged
Boss Height
0.208 inches minimum and 0.228 inches maximum
Pole Quantity
3
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
12 threaded hole and 12 unthreaded hole
Storage Type
general purpose warehouse
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
208.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
magnetic-hydraulic all locations
Trip Release Characteristic
time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
3 toggle
Actuator Function
trip-reset
Actuator Position Designation
at each pole
External Actuator Linkage Arrangement
one, two, and three linked
Internal Trip Release Configuration
series trip all locations
Nominal Thread Size
0.164 inches
Trip Delay Time In Seconds Per Rated Continuous Current
30.000 minimum at 200 pct and 100.000 maximum at 200 pct all locations
Inclosure Protection Type For Which Designed
dustproof and fungus proof
Frequency In Hertz
60.0 all locations
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
6 compression

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
3X1163-20AMP208VAC Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-957-0468?
The FSCG of the NSN 5925-00-957-0468 is 5925
Does the NSN 5925-00-957-0468 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-957-0468 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-957-0468 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-00-957-0468 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-957-0468 was assigned to the Federal Catalog?
It was assigned 64 years ago, on Mon, Jan 1, 1962

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

M39016/45-014M
5945-01-147-2500
Electromagnetic Relay
M39016/45-020L
5945-01-221-3960
Electromagnetic Relay
M39016/45-020M
5945-01-157-0293
Electromagnetic Relay
M39016/45-021L
5945-01-126-9967
Electromagnetic Relay
M39016/45-022L
5945-01-662-4286
Electromagnetic Relay
M39016/45-023L
5945-01-237-3464
Electromagnetic Relay
M39016/45-023M
5945-01-169-3221
Electromagnetic Relay
M39016/45-027L
5945-01-190-7603
Electromagnetic Relay
M39016/47-002M
5945-01-329-1145
Electromagnetic Relay
M39016/48-001L
5945-01-264-2825
Electromagnetic Relay
M39016/48-001M
5945-01-264-2825
Electromagnetic Relay
M39016/48-002L
5945-01-515-2227
Electromagnetic Relay
M39016/48-003M
5945-01-317-0510
Electromagnetic Relay
M39016/5-0002
5945-01-027-3878
Electromagnetic Relay
M39016/5-018L
5945-01-345-7937
Electromagnetic Relay