1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-00-952-5765

5925-00-952-5765

Find complete technical information, availability, and procurement data for: 5925-00-952-5765

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-952-5765 to receive an up to date pricing and availability quote by email.

5925-00-952-5765
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-952-5765
Item Name Code
00136
Assigment Date
01/01/1960 (66 years ago)

0.760 inches nominal body width, 2.062 inches nominal distance between centerlines of mounting facilities parallel to body length, 2.530 inches nominal body length, 1.938 inches nominal center to center distance between terminals parallel to length, single pole type body style

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Body Length
2.530 inches nominal
Body Width
0.760 inches nominal
Center To Center Distance Between Terminals Parallel To Length
1.938 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.062 inches nominal
Fragility Factor
moderately rugged
Boss Height
0.140 inches nominal
Mounting Surface To Terminal End Distance
2.471 inches nominal
Pole Quantity
1
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
2 threaded hole
Storage Type
general purpose warehouse
Special Handling Feature
magnetic
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
1.25 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
32.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3000.0 dc single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
relay trip single location
Nominal Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 minimum at 200 pct and 10.000 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
fungus resistant
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
4 threaded stud

Replaces National Stock Numbers

Below is a list of NSNs that have been officially superseded by this NSN:

NSN Name Date
5925-00-015-7569 No Name Available 08/14/1968

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
70-109LL Circuit Breaker
AM1RA6AC07D-A-1.25-2/50-250AC-SW Circuit Breaker
FHB01-251-2 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-952-5765?
The FSCG of the NSN 5925-00-952-5765 is 5925
Does the NSN 5925-00-952-5765 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-952-5765 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-952-5765 contain precious materials?
Precious metal content is unknown
Does NSN 5925-00-952-5765 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-952-5765 was assigned to the Federal Catalog?
It was assigned 66 years ago, on Fri, Jan 1, 1960

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

600410-03
5950-01-084-2894
Audio Frequency Transformer
600410-1
5330-00-601-1619
Gasket
600411
7021-01-718-9253
D Installation and Equipment Kit
600411-001
6220-01-434-0555
Eyebrow Assy Bezel
600411-003
6220-01-478-7747
Panel Light
600411-1
5998-00-060-9895
Circuit Card Assembly
600411-705-001
6130-01-299-4810
Power Supply
60041100
5999-01-452-5335
Electrical-Electronic Heat Sink
6004113
6520-00-584-2699
Periosteal Elevator
600412-001
6695-01-421-3559
Instrument Mounting Bezel
60041200
5915-01-440-9281
Direct Current Power Filter
6004125
5310-00-419-8272
Flat Washer
600413-001
6695-01-472-9499
Instrument Mounting Bezel
600413-01
5330-00-305-1322
Packing Retainer
600413C
4330-01-124-3702
Fluid Filter Element