DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-942-2658 to receive an up to date pricing and availability quote by email.

5925-00-942-2658
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-942-2658
Item Name Code
00136
Assigment Date
01/02/1966 (60 years ago)

A transformer which is designed so that part or all of its range of operating frequencies is 20 kilohertz (kilocycles) and below. The maximum value may extend into the radio frequency range. It is generally used in the input, output, amplifier, or oscillator stages of audio and sonar devices.

1.562 inches nominal distance between centerlines of mounting facilities parallel to body length, 2.000 inches nominal overall length, 1.266 inches nominal mounting surface to terminal end distance, single pole type body style, 1.188 inches nominal body width

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Overall Length
2.000 inches nominal
Body Width
1.188 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.562 inches nominal
Mounting Surface To Terminal End Distance
1.266 inches nominal
Pole Quantity
1
Mounting Facility Type And Quantity
2 threaded hole
Storage Type
general purpose warehouse
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
3.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
30.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
800.0 dc single location
Circuit Protection Type
overcurrent single location
Trip Release Method
thermal single location
Trip Release Characteristic
instantaneous single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
110.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 push button
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.164 inches
Inclosure Protection Type For Which Designed
weatherproof
Trip Release Ambient Temp Rating
25.0 celsius nominal single location
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
2 screw

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
BAR1059-8 Circuit Breaker
P-5-3M Circuit Breaker
PDM-3 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-942-2658?
The FSCG of the NSN 5925-00-942-2658 is 5925
Does the NSN 5925-00-942-2658 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-942-2658 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-942-2658 contain precious materials?
Precious metal content is unknown
Does NSN 5925-00-942-2658 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-942-2658 was assigned to the Federal Catalog?
It was assigned 60 years ago, on Sun, Jan 2, 1966

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

3291439
2510-01-602-1724
Base as-Joys
329144
6625-00-305-2636
Thermistor Components Matched
329144-1X
2520-01-362-3512
Transmission Cover
3291444-1-1
1660-01-623-6836
Modulating Valve
3291446
4730-00-447-2470
Hose Elbow
329144X
4810-01-552-6258
Valve Cap
329145-12X
5945-01-552-6347
Electromagnetic Relay
329145-24X
4810-01-480-9048
Valve Cap
329145758
5305-00-012-6190
Tapping Screw
3291457PC124
5950-00-645-8685
Power Transformer
3291466
4710-00-389-5564
Metal Tube Assembly
3291466-2
4810-01-655-2425
Flow Control Valve
3291475PC1T085SH1
6625-00-459-7419
Ampere-Hour Meter
3291486
5340-00-428-9595
Loop Clamp
3291487
5340-00-416-4007
Loop Clamp