1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-00-927-5425

5925-00-927-5425

Find complete technical information, availability, and procurement data for: 5925-00-927-5425

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-927-5425 to receive an up to date pricing and availability quote by email.

5925-00-927-5425
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-927-5425
Item Name Code
00136
Assigment Date
08/12/1966 (59 years ago)

5.250 inches nominal center to center distance between terminals parallel to length, 1.380 inches nominal center to center distance between terminals parallel to width, 6.310 inches nominal body length, multipole-single actuator type body style, 4.120 inches nominal body width

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
multipole-single actuator type
Body Length
6.310 inches nominal
Body Width
4.120 inches nominal
Center To Center Distance Between Terminals Parallel To Length
5.250 inches nominal
Center To Center Distance Between Terminals Parallel To Width
1.380 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.880 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.380 inches nominal
Boss Height
0.250 inches nominal
Mounting Surface To Terminal End Distance
9.160 inches nominal
Pole Quantity
3
Mounting Facility Type And Quantity
6 threaded stud
Storage Type
general purpose warehouse
Thread Quantity Per Inch
16
Maximum Continuous Load Current Rating Per Pole
70.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
600.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
18000.0 ac all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
thermal all locations
Trip Release Characteristic
time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole two
Internal Trip Release Configuration
series trip all locations
Nominal Thread Size
0.375 inches
Trip Delay Time In Seconds Per Rated Continuous Current
60.000 nominal at 200 pct all locations
Inclosure Protection Type For Which Designed
fungus resistant
Trip Release Ambient Temp Rating
25.0 celsius nominal all locations
Frequency In Hertz
60.0 all locations
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
6 threaded stud

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
10185899-3 Circuit Breaker
THEFTEF1-136070STIRS Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-927-5425?
The FSCG of the NSN 5925-00-927-5425 is 5925
Does the NSN 5925-00-927-5425 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-927-5425 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-927-5425 contain precious materials?
Precious metal content is unknown
Does NSN 5925-00-927-5425 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-927-5425 was assigned to the Federal Catalog?
It was assigned 59 years ago, on Fri, Aug 12, 1966

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

AV71-019ITEM35
5330-01-381-2051
Gasket
AV71-019ITEM40
5310-00-850-6823
Flat Washer
AV71-019ITEM7
5330-01-184-7717
Gasket
AV71-019PC35
5330-00-558-0540
Gasket
AV71-019PC4
5970-00-669-8823
Washer Insulator
AV71-019PC40
5310-00-850-6823
Flat Washer
AV71-019PC42
4810-00-863-5929
Locking Disc
AV71-019PC48
5331-00-405-5118
O-Ring
AV71-019R ITEM 6
5950-01-146-7391
Electrical Coil
AV71-193PC11
5360-00-308-9093
Extension Helical Spring
AV71-193PC21
5360-00-268-2004
Compression Helical Spring
AV71-193PC34
5330-00-640-9065
Gasket
AV71-193PC68
5360-00-784-4110
Compression Helical Spring
AV71-193PC7
5330-00-285-2694
Gasket
AV71-309-14
5330-00-726-6215
Preformed Packing