1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-00-914-2987

5925-00-914-2987

Find complete technical information, availability, and procurement data for: 5925-00-914-2987

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-914-2987 to receive an up to date pricing and availability quote by email.

5925-00-914-2987
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-914-2987
Item Name Code
00136
Assigment Date
01/01/1960 (66 years ago)

0.315 inches nominal bushing length, single pole type body style, 0.625 inches maximum body width, 0.687 inches nominal center to center distance between terminals parallel to length, 1.750 inches maximum body length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Bushing Length
0.315 inches nominal
Body Length
1.750 inches maximum
Body Width
0.625 inches maximum
Center To Center Distance Between Terminals Parallel To Length
0.687 inches nominal
Mounting Surface To Terminal End Distance
1.635 inches nominal
Pole Quantity
1
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
1 threaded bushing
Storage Type
general purpose warehouse
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
2.1 amperes ac single location
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
500.0 ac single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Ultimate Trip Time Per Pole In Seconds
1.000 minimum and 4.000 maximum single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
shunt trip single location
Nominal Thread Size
0.375 inches
Trip Delay Time In Seconds Per Rated Continuous Current
0.150 minimum at 200 pct and 0.800 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
shockproof and vibrationproof and hermetically sealed
Unpackaged Unit Weight
2.200 ounces nominal
Frequency In Hertz
60.0 single location
Thread Series Designator
unef
Terminal Type And Quantity
3 wire hook

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
512A212 Circuit Breaker
AP-1-3-61-212 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-914-2987?
The FSCG of the NSN 5925-00-914-2987 is 5925
Does the NSN 5925-00-914-2987 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-914-2987 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-914-2987 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-00-914-2987 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-914-2987 was assigned to the Federal Catalog?
It was assigned 66 years ago, on Fri, Jan 1, 1960

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

96204-02551-104
1560-01-619-0203
Air Structural Component Support
96204-02551-105
1560-01-625-2756
Air Structural Component Support
96204-02551-106
1560-01-619-0211
Air Structural Component Support
96204-02551-107
1560-01-625-3723
Air Structural Component Support
96204-02551-108
1560-01-619-0213
Air Structural Component Support
96204-02551-109
1560-01-625-2796
Air Structural Component Support
96204-02551-110
1560-01-625-3317
Air Structural Component Support
96204-02551-111
1560-01-619-0214
Air Structural Component Support
96204-02551-112
1560-01-619-0212
Air Structural Component Support
96204-02551-113
1560-01-625-3326
Air Structural Component Support
96204-02551-114
1560-01-619-0206
Air Structural Component Support
96204-02551-115
1560-01-619-0198
Air Structural Component Support
96204-02551-116
1560-01-625-2481
Air Structural Component Support
96204-02551-117
1560-01-619-0202
Air Structural Component Support
96204-02551-118
1560-01-625-3329
Air Structural Component Support