DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-913-8026 to receive an up to date pricing and availability quote by email.

5925-00-913-8026
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-913-8026
Item Name Code
00136
Assigment Date
01/01/1960 (66 years ago)

3.063 inches nominal center to center distance between terminals parallel to length, 0.990 inches nominal body width, single pole type body style, 2.750 inches nominal distance between centerlines of mounting facilities parallel to body length, 3.719 inches nominal body length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Body Length
3.719 inches nominal
Body Width
0.990 inches nominal
Center To Center Distance Between Terminals Parallel To Length
3.063 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.750 inches nominal
Fragility Factor
moderately rugged
Boss Height
0.156 inches nominal
Mounting Surface To Terminal End Distance
3.239 inches nominal
Pole Quantity
1
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
2 threaded hole
Storage Type
general purpose warehouse
Special Handling Feature
magnetic
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
60.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
4000.0 dc single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic-hydraulic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current
2.500 minimum at 200 pct and 8.500 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
explosion resistant and fungus resistant and moisture resistant
Material
plastic case
Thread Series Designator
unc
Terminal Type And Quantity
2 threaded stud

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
AM1510MG3-60A-50VDC-2 Circuit Breaker
AM1510MG6-60A50VDCCURVE2 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-913-8026?
The FSCG of the NSN 5925-00-913-8026 is 5925
Does the NSN 5925-00-913-8026 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-913-8026 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-913-8026 contain precious materials?
Precious metal content is unknown
Does NSN 5925-00-913-8026 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-913-8026 was assigned to the Federal Catalog?
It was assigned 66 years ago, on Fri, Jan 1, 1960

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

842964PC2
5940-00-159-0248
Stud Terminal
842965-6
5330-01-205-9752
Plain Seal
842965PC2
5940-00-549-2738
Stud Terminal
842965PC3
5940-00-159-0242
Stud Terminal
842967-1
5915-01-332-9392
Radio Frequency Interfere Filter
842967-12
5340-00-290-3626
Loop Clamp
842967-2
5915-01-334-0894
Radio Frequency Interfere Filter
842967-4
5340-00-222-8562
Loop Clamp
842967PC12
5340-00-290-3626
Loop Clamp
842967PC2
5340-00-257-0038
Loop Clamp
842967PC4
5340-00-222-8562
Loop Clamp
842967PC6
5340-00-257-0043
Loop Clamp
842967PC7
5340-00-257-0046
Loop Clamp
842967PC9
5340-00-257-0044
Loop Clamp
8429687
4820-01-340-0187
Check Valve