1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-00-912-2774

5925-00-912-2774

Find complete technical information, availability, and procurement data for: 5925-00-912-2774

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-912-2774 to receive an up to date pricing and availability quote by email.

5925-00-912-2774
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-912-2774
Item Name Code
00136
Assigment Date
07/01/1966 (60 years ago)

0.870 inches minimum and 0.880 inches maximum center to center distance between terminals parallel to length, 1.448 inches minimum and 1.510 inches maximum body length, 0.567 inches minimum and 0.629 inches maximum body width, single pole type body style, 0.360 inches minimum and 0.380 inches maximum bushing length

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
single pole type
Bushing Length
0.360 inches minimum and 0.380 inches maximum
Body Length
1.448 inches minimum and 1.510 inches maximum
Body Width
0.567 inches minimum and 0.629 inches maximum
Center To Center Distance Between Terminals Parallel To Length
0.870 inches minimum and 0.880 inches maximum
Fragility Factor
moderately rugged
Mounting Surface To Terminal End Distance
1.524 inches minimum and 1.586 inches maximum
Pole Quantity
1
Arc Quenching Method
magnetic blowout
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
Storage Type
general purpose warehouse
Thread Quantity Per Inch
32
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac single location
Operating Voltage Type And Rating Per Pole In Volts
110.0 ac single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
500.0 ac single location
Circuit Protection Type
overcurrent single location
Trip Release Method
magnetic single location
Trip Release Characteristic
time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Internal Trip Release Configuration
series trip single location
Nominal Thread Size
0.375 inches
Trip Delay Time In Seconds Per Rated Continuous Current
0.800 minimum at 200 pct and 3.000 maximum at 200 pct single location
Inclosure Protection Type For Which Designed
dustproof and fungus resistant and hermetically sealed
Frequency In Hertz
60.0 single location
Thread Series Designator
unef
Terminal Type And Quantity
2 wire hook

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
505298-1 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-912-2774?
The FSCG of the NSN 5925-00-912-2774 is 5925
Does the NSN 5925-00-912-2774 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-912-2774 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-912-2774 contain precious materials?
Precious metal content is unknown
Does NSN 5925-00-912-2774 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-912-2774 was assigned to the Federal Catalog?
It was assigned 60 years ago, on Fri, Jul 1, 1966

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

RR86S
5325-00-409-5939
Retaining Ring
RR86SP
5325-00-094-3423
Retaining Ring
RR86SS
5325-00-409-5939
Retaining Ring
RR87
5325-00-285-6974
Retaining Ring
RR875
5325-00-435-5279
Retaining Ring
RR87C
5325-00-285-6695
Retaining Ring
RR87S
5325-00-598-6267
Retaining Ring
RR882-01
6020-01-569-4938
Fibe Cable Assembly
RR882-02
6020-01-569-4939
Fibe Cable Assembly
RR882-03
6020-01-569-4941
Fibe Cable Assembly
RR882-04
6020-01-569-4937
Fibe Cable Assembly
RR885-103
6020-01-563-4328
Fibe Cable Assembly
RR885-105
6020-01-563-4334
Fibe Cable Assembly
RR885-107
6020-01-563-4338
Fibe Cable Assembly
RR885-111
6020-01-563-4319
Fibe Cable Assembly