5925-00-882-1597
Find complete technical information, availability, and procurement data for: 5925-00-882-1597
DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-882-1597 to receive an up to date pricing and availability quote by email.
A secondary structure whose function is to reduce drag by providing a streamlined surface or covering.
2.485 inches minimum and 2.515 inches maximum body length, +0.1177 to 0.1214 inches thread pitch diameters, single pole type body style, 0.735 inches minimum and 0.765 inches maximum body width, 1.925 inches minimum and 1.955 inches maximum center to center distance between terminals parallel to length
Product Characteristics
Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.
- Thread Pitch Diameters
- +0.1177 to 0.1214 inches
- Body Style
- single pole type
- Body Length
- 2.485 inches minimum and 2.515 inches maximum
- Body Width
- 0.735 inches minimum and 0.765 inches maximum
- Center To Center Distance Between Terminals Parallel To Length
- 1.925 inches minimum and 1.955 inches maximum
- Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
- 2.047 inches minimum and 2.077 inches maximum
- Switch Contact Arrangement
- single pole, double throw
- Fragility Factor
- moderately rugged
- Boss Height
- 0.125 inches minimum and 0.155 inches maximum
- Mounting Surface To Terminal End Distance
- 2.775 inches minimum and 2.995 inches maximum
- Pole Quantity
- 1
- Arc Quenching Method
- magnetic blowout
- Mounting Facility Type And Quantity
- 2 threaded hole
- Storage Type
- general purpose warehouse
- Special Handling Feature
- magnetic
- Thread Quantity Per Inch
- 32
- Maximum Continuous Load Current Rating Per Pole
- 500.0 milliamperes ac single location
- Operating Voltage Type And Rating Per Pole In Volts
- 250.0 ac single location
- Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
- 1000.0 ac single location
- Circuit Protection Type
- overcurrent single location
- Trip Release Method
- magnetic single location
- Trip Release Characteristic
- time delay single location
- Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
- 125.0 single location
- Reset Method
- manual
- Main Contact Tripping Mechanism Type
- trip free
- Manual Actuator Type And Quantity
- 1 toggle
- Actuator Function
- trip-reset
- Actuator Position Designation
- at pole one
- Auxiliary Switch Function And Quantity
- 1 alarm
- Internal Trip Release Configuration
- series trip single location
- Nominal Thread Size
- 0.138 inches
- Switch Location And Position Designation
- internal at pole one
- Trip Delay Time In Seconds Per Rated Continuous Current
- 3.000 minimum at 200 pct and 10.000 maximum at 200 pct single location
- Inclosure Protection Type For Which Designed
- salt spray proof and shock resistant and vibration resistant and moisture resistant
- Switch Terminal Type
- tab, solder lug
- Switch Current Rating And Type In Amps
- 5.0 ac and 1.0 dc
- Switch Voltage Rating And Type In Volts
- 115.0 ac and 50.0 dc
- Unpackaged Unit Weight
- 4.250 ounces nominal
- Frequency In Hertz
- 60.0 single location
- Material
- plastic case
- Test Data Document
- 05869-711570 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
- Thread Series Designator
- unc
- Terminal Type And Quantity
- 2 threaded stud
Related Parts
This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:
| Part Number | Name |
|---|---|
| 315C861G07 | Circuit Breaker |
| 70-132-6MG6 | Circuit Breaker |
| 711570-015 | Circuit Breaker |
| APL1-19-15-R | Circuit Breaker |
FAQs
Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.
What is the FSCG of the NSN 5925-00-882-1597?
Does the NSN 5925-00-882-1597 have a Schedule B code assigned?
Does NSN 5925-00-882-1597 require demilitarization?
Does NSN 5925-00-882-1597 contain precious materials?
Does NSN 5925-00-882-1597 contain hazardous materials?
When the NSN 5925-00-882-1597 was assigned to the Federal Catalog?
Professional Distribution
Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.
- ITAR Registered
- DDTC Registered
- HAZMAT Certified
- AS9120 Quality Standards
- 100% Quality Inspections
You May Also Like
Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.
Pricing
Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information: