1. Home /
  2. Catalog /
  3. Circuit Breakers /
  4. 5925-00-878-1941

5925-00-878-1941

Find complete technical information, availability, and procurement data for: 5925-00-878-1941

DODParts.com distributes related products varnishes dopes paints, aircraft parts and consumables, electrical parts, fittings and other components for the aerospace and defense industries. Submit the short price quote form for NSN 5925-00-878-1941 to receive an up to date pricing and availability quote by email.

5925-00-878-1941
Federal Supply Group
Electrical and Electronic Equipment Components
Federal Supply Classification
5925 Circuit Breakers
National Stock Number
5925-00-878-1941
Item Name Code
00136
Assigment Date
01/01/1962 (64 years ago)

multipole-single actuator type body style, 9.875 inches nominal center to center distance between terminals parallel to length, 9.000 inches nominal body width, 11.000 inches nominal body length, 4.062 inches nominal body height

Product Characteristics

Below you’ll find the complete technical specifications and performance data for this part, including material details and compliance information.

Body Style
multipole-single actuator type
Body Length
11.000 inches nominal
Body Width
9.000 inches nominal
Body Height
4.062 inches nominal
Center To Center Distance Between Terminals Parallel To Length
9.875 inches nominal
Center To Center Distance Between Terminals Parallel To Width
3.000 inches nominal
Unthreaded Mounting Hole Diameter
0.250 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
9.750 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
3.000 inches nominal
Fragility Factor
moderately rugged
Boss Height
0.250 inches nominal
Pole Quantity
3
Mounting Facility Type And Quantity
4 unthreaded hole
Storage Type
general purpose warehouse
Maximum Continuous Load Current Rating Per Pole
225.0 amperes ac and 225.0 amperes dc all locations
Operating Voltage Type And Rating Per Pole In Volts
600.0 ac and 250.0 dc all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
25000.0 ac and 20000.0 dc all locations
Circuit Protection Type
overcurrent all locations
Trip Release Method
thermal-magnetic all locations
Trip Release Characteristic
instantaneous and time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Reset Method
manual
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
trip-reset
Actuator Position Designation
at pole two
Trip Delay Time In Seconds Per Rated Continuous Current
300.000 minimum at 150 pct and 90.000 minimum at 200 pct all locations
Inclosure Protection Type For Which Designed
general purpose
Trip Release Ambient Temp Rating
40.0 celsius nominal all locations
Frequency In Hertz
60.0 all locations
Material
plastic case
Terminal Type And Quantity
6 compression

Related Parts

This NSN group includes multiple components designed to meet specific performance and operational standards. Each listing provides detailed specs, functionality data, and replacement compatibility information:

Part Number Name
ET5917 Circuit Breaker
JL3B225 Circuit Breaker

FAQs

Find helpful answers about installation, operation, maintenance, compliance, and troubleshooting.

What is the FSCG of the NSN 5925-00-878-1941?
The FSCG of the NSN 5925-00-878-1941 is 5925
Does the NSN 5925-00-878-1941 have a Schedule B code assigned?
Yes, the Schedule B code is 8536200040
Does NSN 5925-00-878-1941 require demilitarization?
Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Does NSN 5925-00-878-1941 contain precious materials?
Item does not contain precious metal.
Does NSN 5925-00-878-1941 contain hazardous materials?
Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
When the NSN 5925-00-878-1941 was assigned to the Federal Catalog?
It was assigned 64 years ago, on Mon, Jan 1, 1962

Professional Distribution

Certified to meet the strict requirements of defense, aerospace, and hazardous materials distribution.

  • ITAR Registered
  • DDTC Registered
  • HAZMAT Certified
  • AS9120 Quality Standards
  • 100% Quality Inspections

You May Also Like

Browse other in-demand NSN parts sourced by professionals in defense, aerospace, and manufacturing sectors. Each component meets strict standards for quality and performance.

Pricing

Submit your request below and our team will respond quickly with up-to-date pricing, delivery estimates, and stock information:

ITAR Registered

Featured Parts

Explore our most requested parts, carefully selected based on customer demand and sourcing activity. Each listing provides current specifications, availability status, and item condition:

6957ED100-1C
6110-01-475-2599
Magnetic Contactor
6957ED101-1C
6110-01-483-1509
Magnetic Contactor
6957ED102-1A1
5945-01-473-5329
Electromagnetic Relay
6957ED102-1C1
5945-01-478-0130
Electromagnetic Relay
6957ED102-2C1
5945-01-478-0135
Electromagnetic Relay
6957ED102-3C1
5945-01-469-0301
Electromagnetic Relay
6957ED102-6A1
5945-01-478-0052
Electromagnetic Relay
6957ED102-6C1
5945-01-479-3290
Electromagnetic Relay
6957ED102-7A1
5945-01-509-6005
Electromagnetic Relay
6957ED104-A1ATN
5945-01-473-5426
Electromagnetic Relay
6957ED104-A1ATR
5945-01-488-4032
Electromagnetic Relay
6957ED104-A2ABN
5925-01-491-2656
Circuit Breaker
6957ED104-A2ATN
5945-01-469-0299
Electromagnetic Relay
6957ED104-A2ATR
5945-01-478-0054
Electromagnetic Relay
6957ED104-A2BTN
5945-01-480-5389
Electromagnetic Relay